[Study on the sterilization effect of plasma jet and plasma activated water on Streptococcus mutans ].
- Source :
-
Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi [Sheng Wu Yi Xue Gong Cheng Xue Za Zhi] 2023 Jun 25; Vol. 40 (3), pp. 559-565. - Publication Year :
- 2023
-
Abstract
- To explore the effects of plasma jet (PJ) and plasma activated water (PAW) on the sterilization of Streptococcus mutans ( S. mutans ) and compare the advantages and disadvantages of the two methods, so as to provide a basis for plasma treatment of dental caries and to enrich the treatment means of dental caries, an atmospheric pressure plasma excitation system was built, and the effects of PJ and PAW on the sterilization rate of S. mutans and the changes of temperature and pH during treatment were studied under different excitation voltage ( U <subscript> e </subscript> ) and different excitation time ( t <subscript> e </subscript> ). The results showed that in the PJ treatment, the difference in the survival rate of S. mutans between the treatment group and the control group was statistically significant ( P = 0.007, d =2.66) when U <subscript> e </subscript> = 7 kV and t <subscript> e </subscript> = 60 s, and complete sterilization was achieved at U <subscript> e </subscript> = 8 kV and t <subscript> e </subscript> = 120 s in the PJ treatment. In contrast, in the PAW treatment, the difference in the survival rate of S. mutans between the treatment group and the control group was statistically significant ( P = 0.029, d = 1.71) when U <subscript> e </subscript> = 7 kV and t <subscript> e </subscript> = 30 s, and complete sterilization was achieved with PAW treatment when U <subscript> e </subscript> = 9 kV and t <subscript> e </subscript> = 60 s. Results of the monitoring of temperature and pH showed that the maximum temperature rise during PJ and PAW treatment did not exceed 4.3 °C, while the pH value after PAW treatment would drop to a minimum of 3.02. In summary, the optimal sterilization parameters for PJ were U <subscript> e </subscript> =8 kV and 90 s < t <subscript> e </subscript> ≤ 120 s, while the optimal sterilization parameters for PAW were U <subscript> e </subscript> = 9 kV and 30 s< t <subscript> e </subscript> ≤ 60 s. Both treatment methods achieved non-thermal sterilization of S. mutans , where PJ required only a smaller U <subscript> e </subscript> to achieve complete sterilization, while at pH < 4.7, PAW only required a shorter t <subscript> e </subscript> to achieve complete sterilization, but its acidic environment could cause some chemical damage to the teeth. This study can provide some reference value for plasma treatment of dental caries.
- Subjects :
- Humans
Sterilization
Temperature
Water
Streptococcus mutans
Dental Caries therapy
Subjects
Details
- Language :
- Chinese
- ISSN :
- 1001-5515
- Volume :
- 40
- Issue :
- 3
- Database :
- MEDLINE
- Journal :
- Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi
- Publication Type :
- Academic Journal
- Accession number :
- 37380397
- Full Text :
- https://doi.org/10.7507/1001-5515.202212030