Back to Search Start Over

[Metagenomic next-generation sequencing of plasma for the identification of bloodstream infectious pathogens in severe aplastic anemia].

Authors :
Li Y
Xiong YZ
Fan HH
Jing LP
Li JP
Lin QS
Xu CH
Li Y
Ye L
Jiao M
Yang Y
Li Y
Yang WR
Peng GX
Zhou K
Zhao X
Zhang L
Zhang FK
Source :
Zhonghua xue ye xue za zhi = Zhonghua xueyexue zazhi [Zhonghua Xue Ye Xue Za Zhi] 2023 Mar 14; Vol. 44 (3), pp. 236-241.
Publication Year :
2023

Abstract

Objective: To analyze the diagnostic value of cell-free plasma metagenomic next-generation sequencing (mNGS) pathogen identification for severe aplastic anemia (SAA) bloodstream infection. Methods: From February 2021 to February 2022, mNGS and conventional detection methods (blood culture, etc.) were used to detect 33 samples from 29 consecutive AA patients admitted to the Anemia Diagnosis and Treatment Center of the Hematology Hospital of the Chinese Academy of Medical Sciences to assess the diagnostic consistency of mNGS and conventional detection, as well as the impact on clinical treatment benefits and clinical accuracy. Results: ①Among the 33 samples evaluated by mNGS and conventional detection methods, 25 cases (75.76%) carried potential pathogenic microorganisms. A total of 72 pathogenic microorganisms were identified from all cases, of which 65 (90.28%) were detected only by mNGS. ②All 33 cases were evaluated for diagnostic consistency, of which 2 cases (6.06%) were Composite, 18 cases (54.55%) were mNGS only, 2 cases (6.06%) were Conventional method only, 1 case (3.03%) was both common compliances (mNGS/Conventional testing) , and 10 cases (30.3%) were completely non-conforming (None) . ③All 33 cases were evaluated for clinical treatment benefit. Among them, 8 cases (24.24%) received Initiation of targeted treatment, 1 case (3.03%) received Treatment de-escalation, 13 cases (39.39%) received Confirmation, and the remaining 11 cases (33.33%) received No clinical benefit. ④ The sensitivity of 80.77%, specificity of 70.00%, positive predictive value of 63.64%, negative predictive value of 84.85%, positive likelihood ratio of 2.692, and negative likelihood ratio of 0.275 distinguished mNGS from conventional detection methods (21/12 vs 5/28, P <0.001) . Conclusion: mNGS can not only contribute to accurately diagnosing bloodstream infection in patients with aplastic anemia, but can also help to guide accurate anti-infection treatment, and the clinical accuracy is high.

Details

Language :
Chinese
ISSN :
0253-2727
Volume :
44
Issue :
3
Database :
MEDLINE
Journal :
Zhonghua xue ye xue za zhi = Zhonghua xueyexue zazhi
Publication Type :
Academic Journal
Accession number :
37356986
Full Text :
https://doi.org/10.3760/cma.j.issn.0253-2727.2023.03.010