Evaluation of the uniformity of UVA LED illumination on flat surfaces: Discrete ordinate method, single axis, and surface scanning radiometry.
- Source :
-
Heliyon [Heliyon] 2023 May 20; Vol. 9 (6), pp. e16557. Date of Electronic Publication: 2023 May 20 (Print Publication: 2023). - Publication Year :
- 2023
-
Abstract
- Uniform illumination from UVA LED lamps is a crucial design characteristic for a range of industries including photocatalytic applications. In this work, radiometry and the discrete ordinate method (DOM) are used to determine the ideal target surface size and working distance from a UVA LED lamp for highly uniform illumination. Horizontal incident radiation and full surface incident radiation measurements were conducted using a scanning radiometry technique. It is shown that horizontal incident and full surface incident radiation measurements show good agreement for uniformity measurements over a range of working distances, with maximum uniformity (2.6% and 3.6% standard deviation respectively) over the measured range found at 15 mm working distance. DOM simulation results showed good agreement with radiometry for power and incident radiation measurements, whilst indicating a maximum uniformity at 20 mm working distance. These results demonstrate that DOM simulations can be used as a fast, low cost, and reliable indication of surface uniformity, peak surface irradiance, and power measurements in the design of UV lamps for industrial and academic applications.<br />Competing Interests: The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.<br /> (© 2023 The Authors.)
Details
- Language :
- English
- ISSN :
- 2405-8440
- Volume :
- 9
- Issue :
- 6
- Database :
- MEDLINE
- Journal :
- Heliyon
- Publication Type :
- Academic Journal
- Accession number :
- 37251462
- Full Text :
- https://doi.org/10.1016/j.heliyon.2023.e16557