Back to Search Start Over

Limited concordance of heparin/platelet factor 4 antibody assays for the diagnosis of heparin-induced thrombocytopenia: an analysis of the TORADI-HIT study.

Authors :
Hammerer-Lercher A
Nilius H
Studt JD
Tsakiris DA
Greinacher A
Mendez A
Schmidt A
Wuillemin WA
Gerber B
Kremer Hovinga JA
Vishnu P
Graf L
Bakchoul T
Nagler M
Source :
Journal of thrombosis and haemostasis : JTH [J Thromb Haemost] 2023 Sep; Vol. 21 (9), pp. 2559-2568. Date of Electronic Publication: 2023 May 27.
Publication Year :
2023

Abstract

Background: Anecdotal reports suggest that the correlation between heparin/platelet factor 4 (PF4) antibody assays for the diagnosis of heparin-induced thrombocytopenia (HIT) is limited.<br />Objectives: To investigate the correlation between widely used assays and examine possible factors contributing to variability.<br />Methods: This is a large, prospective cohort study with 10 participating tertiary care hospitals including 1393 patients with suspected HIT in clinical practice. HIT was defined by a positive heparin-induced platelet activation (HIPA) assay (washed platelet reference standard test). Three different immunoassays were used to measure heparin/PF4 antibodies: chemiluminescent immunoassay, enzyme-linked immunosorbent assay, and particle gel immunoassay. Various factors that could influence the assays were examined: sex (male or female), age (<65 years or ≥65 years), unfractionated heparin exposure, presence of thrombosis, cardiovascular surgery, and intensive care unit. Spearman's correlation coefficients were calculated. Z-scores and diagnostic odds ratios were determined in the aforementioned subgroups of patients.<br />Results: Among 1393 patients, 119 were classified as HIT-positive (prevalence, 8.5%). The median 4Ts score was 5 (IQR, 4-6) in patients with HIT compared with 3 (IQR, 2-4) in patients without HIT. Correlations (r <subscript>s</subscript> ) between immunoassays were weak (0.53-0.65). Inconsistencies between immunoassays could not be explained by further analyses of z-scored test results and diagnostic odds ratios in subgroups of patients.<br />Conclusion: The correlation between widely used heparin/PF4 antibody assays was weak, and key factors could not explain this variability. Standardization of immunoassays is requested to improve comparability.<br /> (Copyright © 2023 International Society on Thrombosis and Haemostasis. Published by Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1538-7836
Volume :
21
Issue :
9
Database :
MEDLINE
Journal :
Journal of thrombosis and haemostasis : JTH
Publication Type :
Academic Journal
Accession number :
37247669
Full Text :
https://doi.org/10.1016/j.jtha.2023.05.016