Back to Search Start Over

Are Two- and Three-Dimensional Computed Tomographic Scan Measurements of Tibial Tubercle-Trochlear Groove Distance Equivalent? A Comparative Study.

Authors :
Teo SH
Ong TK
Merican AM
Hashim MS
Ng WM
Al-Fayyadh MZM
Ali MRM
Source :
Indian journal of orthopaedics [Indian J Orthop] 2023 Apr 05; Vol. 57 (6), pp. 847-855. Date of Electronic Publication: 2023 Apr 05 (Print Publication: 2023).
Publication Year :
2023

Abstract

Background: Accurate planning for patellar instability correction is important in obtaining good post-operative outcome. The main challenge in the current two-dimensional (2-D) computed tomographic (CT) scans method is the difficulty in choosing reliable bony landmarks. This study aimed to compare the reliabilities between the 2-D and three-dimensional (3-D) methods of measuring tibial tubercle-trochlear groove (TT-TG) distance. We hypothesize that the proposed 3-D method will result in measurements with narrower error margin, providing higher reliability and accuracy.<br />Materials and Methods: We traced CT scans of 106 knees with no patellofemoral pathology from 59 subjects from the database system and converted all 2-D images into 3-D models to determine the values for each parameter. We compared the intra- and interobserver reliability of each method using intraclass correlation (ICC) and Bland-Altman method.<br />Results: The values of TT-TG measured by 2-D and 3-D methods were 16.1 ± 4.6 mm and 16.2 ± 4.2 mm, respectively. The ICC values of both methods were comparable (95% limits of agreement between the same observer: - 3.3 to 3.8 mm versus - 2.4 to 2.7 mm and different observers: - 4.3 to 4.9 mm versus - 3.9 to 2.7 mm), with 3-D method results in narrower limits of agreement.<br />Conclusion: TT-TG measurement is reliable using the 2-D method without using advanced radiographic software. The 3-D method of measuring TT-TG provides measurement with narrower variation when compared with the 2-D method. However, both TT-TG distances' measurement methods in the current study were comparable as the variations are not significant.<br />Competing Interests: Conflict of InterestAll authors declare that there are no conflicting interests.<br /> (© Indian Orthopaedics Association 2023, Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.)

Details

Language :
English
ISSN :
0019-5413
Volume :
57
Issue :
6
Database :
MEDLINE
Journal :
Indian journal of orthopaedics
Publication Type :
Academic Journal
Accession number :
37214363
Full Text :
https://doi.org/10.1007/s43465-023-00874-x