Back to Search Start Over

Intramuscular coherence enables robust assessment of modulated supra-spinal input in human gait: an inter-dependence study of visual task and walking speed.

Authors :
Zipser-Mohammadzada F
Scheffers MF
Conway BA
Halliday DM
Zipser CM
Curt A
Schubert M
Source :
Experimental brain research [Exp Brain Res] 2023 Jun; Vol. 241 (6), pp. 1675-1689. Date of Electronic Publication: 2023 May 18.
Publication Year :
2023

Abstract

Intramuscular high-frequency coherence is increased during visually guided treadmill walking as a consequence of increased supra-spinal input. The influence of walking speed on intramuscular coherence and its inter-trial reproducibility need to be established before adoption as a functional gait assessment tool in clinical settings. Here, fifteen healthy controls performed a normal and a target walking task on a treadmill at various speeds (0.3 m/s, 0.5 m/s, 0.9 m/s, and preferred) during two sessions. Intramuscular coherence was calculated between two surface EMG recordings sites of the Tibialis anterior muscle during the swing phase of walking. The results were averaged across low-frequency (5-14 Hz) and high-frequency (15-55 Hz) bands. The effect of speed, task, and time on mean coherence was assessed using three-way repeated measures ANOVA. Reliability and agreement were calculated with the intra-class correlation coefficient and Bland-Altman method, respectively. Intramuscular coherence during target walking was significantly higher than during normal walking across all walking speeds in the high-frequency band as obtained by the three-way repeated measures ANOVA. Interaction effects between task and speed were found for the low- and high-frequency bands, suggesting that task-dependent differences increase at higher walking speeds. Reliability of intramuscular coherence was moderate to excellent for most normal and target walking tasks in all frequency bands. This study confirms previous reports of increased intramuscular coherence during target walking, while providing first evidence for reproducibility and robustness of this measure as a requirement to investigate supra-spinal input.Trial registration Registry number/ClinicalTrials.gov Identifier: NCT03343132, date of registration 2017/11/17.<br /> (© 2023. The Author(s).)

Details

Language :
English
ISSN :
1432-1106
Volume :
241
Issue :
6
Database :
MEDLINE
Journal :
Experimental brain research
Publication Type :
Academic Journal
Accession number :
37199775
Full Text :
https://doi.org/10.1007/s00221-023-06635-4