Back to Search Start Over

Intermediate Outcomes of the Novel 63-μm Gelatin Microstent versus the Conventional 45-μm Gelatin Microstent.

Authors :
Hussein IM
De Francesco T
Ahmed IIK
Source :
Ophthalmology. Glaucoma [Ophthalmol Glaucoma] 2023 Nov-Dec; Vol. 6 (6), pp. 580-591. Date of Electronic Publication: 2023 May 09.
Publication Year :
2023

Abstract

Purpose: To determine intermediate intraocular pressure (IOP)-lowering and adverse event profile of the 63-μm gelatin microstent (Xen63) with mitomycin C (MMC) compared with the 45-μm gelatin microstent (Xen45) with MMC.<br />Design: Single center, consecutive, retrospective cohort study.<br />Participants: Eighty-four glaucomatous eyes (42 63-μm gelatin microstent and 42 45-μm gelatin microstent) with or without previous subconjunctival glaucoma surgery.<br />Methods: Consecutive eyes that underwent 63-μm gelatin microstent implantation with MMC from February 2020 to June 2021 were compared with eyes that underwent 45-μm gelatin microstent implantation with MMC. Standalone and combined cases with phacoemulsification were included.<br />Main Outcome Measures: Primary outcome was the hazard ratio of failure of 45-μm gelatin microstent vs. 63-μm gelatin microstent eyes at 12 months, with failure defined as 2 consecutive IOPs, (1) >17 mmHg, (2) <6 mmHg with 2 lines of vision loss, or (3) <20% reduction from baseline IOP, without (complete) or with (qualified) glaucoma medications. Secondary outcomes included IOP thresholds of 14 mmHg and 21 mmHg, postoperative IOP, medications, adverse events, interventions, and reoperations.<br />Results: The complete success rate was higher in the 63-μm gelatin microstent group (59.5% vs. 28.6%, P = 0.009) at the primary IOP threshold of 6 to 17 mmHg but did not differ significantly for qualified success (66.7% vs. 45.2%, P = 0.08). The crude hazard ratio of failure of 45-μm gelatin microstent relative to 63-μm gelatin microstent was 2.28 (95% confidence interval [CI], 1.21-4.32), and the adjusted hazard ratio was 7.90 (95% CI, 2.12-29.43). 63-μm gelatin microstent eyes had significantly lower mean IOP (12.7 ± 4.8 vs. 15.5 ± 5.1 mmHg, P = 0.001) and fewer medication classes (0.6 ± 1.1 vs. 1.7 ± 1.6 medications, P = 0.0005), with the degree of reduction in IOP and medication count being significantly greater in 63-μm gelatin microstent eyes. There were 28 and 21 distinct interventions in 63-μm gelatin microstent and 45-μm gelatin microstent eyes respectively, with 11.9% of eyes undergoing needling in each group. There were 34 and 19 distinct adverse events, in 63-μm gelatin microstent and 45-μm gelatin microstent eyes, respectively, most of which were early and transient. Nine Xen63 eyes (21.4%) and 6 45-μm gelatin microstent eyes (14.3%) underwent reoperation.<br />Conclusions: 63-μm gelatin microstent resulted in higher surgical success rates and fewer medications compared with 45-μm gelatin microstent. This was tempered by more postoperative interventions and adverse events, although most were transient.<br />Financial Disclosure(s): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.<br /> (Copyright © 2023 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
2589-4196
Volume :
6
Issue :
6
Database :
MEDLINE
Journal :
Ophthalmology. Glaucoma
Publication Type :
Academic Journal
Accession number :
37169174
Full Text :
https://doi.org/10.1016/j.ogla.2023.05.001