One assay to test them all: Multiplex assays for expansion of respiratory virus surveillance.
- Source :
-
Frontiers in medicine [Front Med (Lausanne)] 2023 Apr 24; Vol. 10, pp. 1161268. Date of Electronic Publication: 2023 Apr 24 (Print Publication: 2023). - Publication Year :
- 2023
-
Abstract
- Molecular multiplex assays (MPAs) for simultaneous detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), influenza and respiratory syncytial virus (RSV) in a single RT-PCR reaction reduce time and increase efficiency to identify multiple pathogens with overlapping clinical presentation but different treatments or public health implications. Clinical performance of XpertXpress <superscript>®</superscript> SARS-CoV-2/Flu/RSV (Cepheid, GX), TaqPath™ COVID-19, FluA/B, RSV Combo kit (Thermo Fisher Scientific, TP), and PowerChek™ SARS-CoV-2/Influenza A&B/RSV Multiplex RT-PCR kit II (KogeneBiotech, PC) was compared to individual Standards of Care (SoC). Thirteen isolates of SARS-CoV-2, human seasonal influenza, and avian influenza served to assess limit of detection (LoD). Then, positive and negative residual nasopharyngeal specimens, collected under public health surveillance and pandemic response served for evaluation. Subsequently, comparison of effectiveness was assessed. The three MPAs confidently detect all lineages of SARS-CoV-2 and influenza viruses. MPA-LoDs vary from 1 to 2 Log10 differences from SoC depending on assay and strain. Clinical evaluation resulted in overall agreement between 97 and 100%, demonstrating a high accuracy to detect all targets. Existing differences in costs, testing burden and implementation constraints influence the choice in primary or community settings. TP, PC and GX, reliably detect SARS-CoV-2, influenza and RSV simultaneously, with reduced time-to-results and simplified workflows. MPAs have the potential to enhance diagnostics, surveillance system, and epidemic response to drive policy on prevention and control of viral respiratory infections.<br />Competing Interests: JF, MG, OO, and CU were employed by Thermo Fisher Scientific. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.<br /> (Copyright © 2023 Boukli, Flamand, Chea, Heng, Keo, Sour, In, Chhim, Chhor, Kruy, Feenstra, Gandhi, Okafor, Ulekleiv, Auerswald, Horm and Karlsson.)
Details
- Language :
- English
- ISSN :
- 2296-858X
- Volume :
- 10
- Database :
- MEDLINE
- Journal :
- Frontiers in medicine
- Publication Type :
- Academic Journal
- Accession number :
- 37168265
- Full Text :
- https://doi.org/10.3389/fmed.2023.1161268