Back to Search Start Over

Prevalence of malignant or possibly malignant renal masses among homogeneous low-attenuation masses that are too small to characterize at computed tomography.

Authors :
Qarni B
McGrath T
Aldhufian M
Schieda N
Source :
Abdominal radiology (New York) [Abdom Radiol (NY)] 2023 Aug; Vol. 48 (8), pp. 2628-2635. Date of Electronic Publication: 2023 May 11.
Publication Year :
2023

Abstract

Background: Homogeneous low-attenuation renal masses that are too small to characterize (tstc) are considered clinically insignificant; however, based primarily on expert opinion.<br />Objective: To determine the prevalence of malignant or possibly malignant masses among homogeneous low-attenuation renal masses that are tstc.<br />Materials and Methods: This retrospective cross-sectional study evaluated 75 patients with 104 tstc who underwent renal CT and MRI between Jan 2016 and Jul 2022. Low-attenuation renal masses measuring < 1 cm in size were identified and, independently evaluated by two blinded radiologists measuring attenuation (Hounsfield Units, HU) at non-contrast enhanced CT (NECT) and nephrographic phase contrast-enhanced (CE)-CT when possible. Reference standard for benign cyst was MRI and for other renal masses was pathology or MRI showing enhancement.<br />Results: Average tstc size was 6 ± 2 (range 2-10) mm. Considering only incidental tstc (CT performed for another reason), 100% (98/98, 95%CI 96-100%) tstc were benign. Overall, considering both incidental and tstc referred for further characterization, there were 94% (98/104; 95% Confidence Intervals [CIs] 88-98%) benign cysts and 6% (6/104; 95%CI 2-12%) other masses (1 Bosniak 2F cystic mass, 2 probable renal cell carcinoma (RCC), three metastases). Pseudoenhancement, attenuation change > 10 HU or > 20 HU, was present in 29% (15/59) and 12% (7/59) benign cysts. All six other masses enhanced by > 20 HU. CECT threshold of ≤ 30 HU correctly classified 62% of benign cysts (61/98). All six other masses measured > 30 HU at CECT.<br />Conclusion: The prevalence of malignant or possibly malignant renal masses among homogeneous low-attenuation too small to characterize masses among incidental tstc masses is near zero. Attenuation measurements misclassify a substantial proportion of these cysts, likely due to their small size.<br /> (© 2023. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.)

Details

Language :
English
ISSN :
2366-0058
Volume :
48
Issue :
8
Database :
MEDLINE
Journal :
Abdominal radiology (New York)
Publication Type :
Academic Journal
Accession number :
37166461
Full Text :
https://doi.org/10.1007/s00261-023-03946-6