A deep learning-based approach for statistical robustness evaluation in proton therapy treatment planning: a feasibility study.

Authors :
Vazquez I
Gronberg MP
Zhang X
Court LE
Zhu XR
Frank SJ
Yang M
Source :
Physics in medicine and biology [Phys Med Biol] 2023 Apr 26; Vol. 68 (9). Date of Electronic Publication: 2023 Apr 26.
Publication Year :
2023

Abstract

Objective . Robustness evaluation is critical in particle radiotherapy due to its susceptibility to uncertainties. However, the customary method for robustness evaluation only considers a few uncertainty scenarios, which are insufficient to provide a consistent statistical interpretation. We propose an artificial intelligence-based approach that overcomes this limitation by predicting a set of percentile dose values at every voxel and allows for the evaluation of planning objectives at specific confidence levels. Approach . We built and trained a deep learning (DL) model to predict the 5th and 95th percentile dose distributions, which corresponds to the lower and upper bounds of a two-tailed 90% confidence interval (CI), respectively. Predictions were made directly from the nominal dose distribution and planning computed tomography scan. The data used to train and test the model consisted of proton plans from 543 prostate cancer patients. The ground truth percentile values were estimated for each patient using 600 dose recalculations representing randomly sampled uncertainty scenarios. For comparison, we also tested whether a common worst-case scenario (WCS) robustness evaluation (voxel-wise minimum and maximum) corresponding to a 90% CI could reproduce the ground truth 5th and 95th percentile doses. Main results . The percentile dose distributions predicted by DL yielded excellent agreements with the ground truth dose distributions, with mean dose errors below 0.15 Gy and average gamma passing rates (GPR) at 1 mm/1% above 93.9, which were substantially better than the WCS dose distributions (mean dose error above 2.2 Gy and GPR at 1 mm/1% below 54). We observed similar outcomes in a dose-volume histogram error analysis, where the DL predictions generally yielded smaller mean errors and standard deviations than the WCS evaluation doses. Significance . The proposed method produces accurate and fast predictions (∼2.5 s for one percentile dose distribution) for a given confidence level. Thus, the method has the potential to improve robustness evaluation.<br /> (© 2023 Institute of Physics and Engineering in Medicine.)

Details

Language :
English
ISSN :
1361-6560
Volume :
68
Issue :
9
Database :
MEDLINE
Journal :
Physics in medicine and biology
Publication Type :
Academic Journal
Accession number :
37040785
Full Text :
https://doi.org/10.1088/1361-6560/accc08