Back to Search
Start Over
Hardware Infection From Surgical Stabilization of Rib Fractures Is Lower Than Previously Reported.
- Source :
-
Cureus [Cureus] 2023 Mar 03; Vol. 15 (3), pp. e35732. Date of Electronic Publication: 2023 Mar 03 (Print Publication: 2023). - Publication Year :
- 2023
-
Abstract
- Introduction Surgical stabilization of rib fractures (SSRF) is an emerging therapy for the treatment of patients with traumatic rib fractures. Despite the demonstrated benefits of SSRF, there remains a paucity of literature regarding the complications from SSRF, especially those related to hardware infection. Currently, literature quotes hardware infection rates as high as 4%. We hypothesize that the hardware infection rate is much lower than currently published. Methods This is an IRB-approved, four-year multicenter descriptive review of prospectively collected data from January 2016 to June 2022. All patients undergoing SSRF were included in the study. Exclusion criteria included those patients less that 18 years of age. Basic demographics were obtained: age, gender, Injury Severity Score (ISS), Abbreviate Injury Scale-chest (AIS-chest), flail chest (yes/no), delayed SSRF more than two weeks (yes/no), number of patients with a pre-SSRF chest tube, and number of ribs fixated. Primary outcome was hardware infection. Secondary outcomes included mortality rate and hospital length of stay (HLOS). Basic descriptive statistics were utilized for analysis. Results A total of 453 patients met criteria for inclusion in the study. Mean age was 63 ± 15.2 years and 71% were male. Mean ISS was 17.3 ± 8.5 with a mean AIS-chest of 3.2 ± 0.5. Flail chest (three consecutive ribs with two or more fractures on each rib) accounted for 32% of patients. Forty-two patients (9.3%) underwent delayed SSRF. The average number of ribs stabilized was 4.75 ± 0.71. When analyzing the primary outcome, only two patients (0.4%) developed a hardware infection requiring reoperation to remove the plates. Overall HLOS was 10.5 ± 6.8 days. Five patients suffered a mortality (1.1%), all five with ISS scores higher than 15 suggesting significant polytrauma. Conclusion This is the largest case series to date examining SSRF hardware infection. The incidence of SSRF hardware infection is very low (<0.5%), much less than quoted in current literature. Overall, SSRF is a safe procedure with low morbidity and mortality.<br />Competing Interests: The authors have declared financial relationships, which are detailed in the next section.<br /> (Copyright © 2023, Bauman et al.)
Details
- Language :
- English
- ISSN :
- 2168-8184
- Volume :
- 15
- Issue :
- 3
- Database :
- MEDLINE
- Journal :
- Cureus
- Publication Type :
- Academic Journal
- Accession number :
- 37016647
- Full Text :
- https://doi.org/10.7759/cureus.35732