Back to Search
Start Over
Effects of impermeable and semipermeable glove materials on resolution of inflammation and epidermal barrier impairment after experimental skin irritation.
- Source :
-
Contact dermatitis [Contact Dermatitis] 2023 Jul; Vol. 89 (1), pp. 26-36. Date of Electronic Publication: 2023 Apr 04. - Publication Year :
- 2023
-
Abstract
- Background: Semipermeable membranes might be suitable for glove liners or comfort gloves in individuals with irritant contact dermatitis (ICD).<br />Objectives: To evaluate the effects of different glove materials on inflammation and epidermal barrier impairment after experimental skin irritation.<br />Methods: Nine test areas on the volar forearms of 24 healthy volunteers were irritated with sodium lauryl sulfate (1%) and afterward covered for 6 days (6 or 8 h/day) with semipermeable Sympatex (SYM), vinyl (OCC), combinations of vinyl with Sympatex (SYM/OCC) or cotton (COT/OCC), or left uncovered (CON). Up to day 10, measurements of transepidermal water loss (TEWL), erythema (a*), skin humidity (SH) and visual scoring (VS) were applied.<br />Results: No significant differences in skin parameters were found between COT/OCC and SYM/OCC as well as between each of the combinations and CON. SYM, COT/OCC and SYM/OCC led to better results for most skin parameters than OCC alone.<br />Conclusions: Occlusive material has a negative impact on skin barrier recovery and inflammation after skin irritation whereas SYM is not inferior to uncovered areas indicating good tolerability. Altogether, the data suggest that SYM is a useful alternative to COT as material for glove liners and comfort gloves in ICD patients.<br /> (© 2023 The Authors. Contact Dermatitis published by John Wiley & Sons Ltd.)
Details
- Language :
- English
- ISSN :
- 1600-0536
- Volume :
- 89
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Contact dermatitis
- Publication Type :
- Academic Journal
- Accession number :
- 37015218
- Full Text :
- https://doi.org/10.1111/cod.14317