3D shape reconstruction of the femur from planar X-ray images using statistical shape and appearance models.

Authors :
Nolte D
Xie S
Bull AMJ
Source :
Biomedical engineering online [Biomed Eng Online] 2023 Mar 24; Vol. 22 (1), pp. 30. Date of Electronic Publication: 2023 Mar 24.
Publication Year :
2023

Abstract

Major trauma is a condition that can result in severe bone damage. Customised orthopaedic reconstruction allows for limb salvage surgery and helps to restore joint alignment. For the best possible outcome three dimensional (3D) medical imaging is necessary, but its availability and access, especially in developing countries, can be challenging. In this study, 3D bone shapes of the femur reconstructed from planar radiographs representing bone defects were evaluated for use in orthopaedic surgery. Statistical shape and appearance models generated from 40 cadaveric X-ray computed tomography (CT) images were used to reconstruct 3D bone shapes. The reconstruction simulated bone defects of between 0% and 50% of the whole bone, and the prediction accuracy using anterior-posterior (AP) and anterior-posterior/medial-lateral (AP/ML) X-rays were compared. As error metrics for the comparison, measures evaluating the distance between contour lines of the projections as well as a measure comparing similarities in image intensities were used. The results were evaluated using the root-mean-square distance for surface error as well as differences in commonly used anatomical measures, including bow, femoral neck, diaphyseal-condylar and version angles between reconstructed surfaces from the shape model and the intact shape reconstructed from the CT image. The reconstructions had average surface errors between 1.59 and 3.59 mm with reconstructions using the contour error metric from the AP/ML directions being the most accurate. Predictions of bow and femoral neck angles were well below the clinical threshold accuracy of 3°, diaphyseal-condylar angles were around the threshold of 3° and only version angle predictions of between 5.3° and 9.3° were above the clinical threshold, but below the range reported in clinical practice using computer navigation (i.e., 17° internal to 15° external rotation). This study shows that the reconstructions from partly available planar images using statistical shape and appearance models had an accuracy which would support their potential use in orthopaedic reconstruction.<br /> (© 2023. The Author(s).)

Details

Language :
English
ISSN :
1475-925X
Volume :
22
Issue :
1
Database :
MEDLINE
Journal :
Biomedical engineering online
Publication Type :
Academic Journal
Accession number :
36964560
Full Text :
https://doi.org/10.1186/s12938-023-01093-z