Abstract

Background: Penile duplex Doppler ultrasound in combination with intra-cavernous injection of vasoactive agents (PDDU-ICI) is the most accepted tool for diagnosis of arteriogenic erectile dysfunction (AED), but is invasive, time consuming and at risk of side effects.<br />Objectives: The purpose of this pilot study is to evaluate the potential of transrectal color Doppler ultrasound (TR-CDU) of the common penile arteries as a non-invasive method for the diagnosis of AED.<br />Materials and Methods: A consecutive series of 61 men consulting for erectile dysfunction (ED) and 20 controls underwent TR-CDU examination, aged from 40 to 80 years. Sonographic parameters were correlated with the International Index of Erectile Function, short form (IIEF-5). Sensitivity and specificity were calculated and the areas under the receiver operating characteristic curves (AUC) were compared to evaluate the diagnostic performance.<br />Results: Receiver operating characteristic curve analysis showed no significant results for IIEF-5 score ⩾21 in relation to the Doppler parameters. However, we found a good diagnostic performance for patients with ED grading from moderate to severe at IIEF-5. In this cohort, we found that mean peak systolic velocity >15.8 cm/s predicted IIEF-5 ⩾17 (AUC = 0.73, p  = 0.002) with 61.5% sensitivity and 85.7% specificity. Mean end diastolic velocity >1.46 cm/s predicted IIEF-5 ⩾17 (AUC = 0.68, p  = 0.02) with 80.7% sensitivity and 52.4% specificity. Mean resistance index ⩽0.72 predicted IIEF-5 ⩾17 (AUC = 0.71, p  = 0.004) with 46.2% sensitivity and 95.2% specificity. Mean pulsatility index ⩽1.41 predicted IIEF-5 ⩾17 (AUC = 0.75, p  = 0.0005) with 48.5% sensitivity and 95.14% specificity.<br />Conclusions: TR-CDU proved to be a feasible and non-invasive procedure, easily repeatable and not time consuming, overcoming the limits of PDDU-ICI. Diagnostic accuracy seems to be promising in discriminating patients with normal erectile function or mild dysfunction from those with moderate to severe ED. However, these findings need to be verified in future controlled randomized clinical trials.

Details

Language :
English
ISSN :
1724-6075
Volume :
90
Issue :
3
Database :
MEDLINE
Journal :
Urologia
Publication Type :
Academic Journal
Accession number :
36932946
Full Text :
https://doi.org/10.1177/03915603231162388