Back to Search Start Over

Voluntary versus mechanically-induced deep inspiration breath-hold for left breast cancer: A randomized controlled trial.

Authors :
Vander Veken L
Van Ooteghem G
Razavi A
Da Rita Quaresma S
Longton E
Kirkove C
Ledoux B
Vandermeulen A
Abdel Massih C
Henderickx P
Gabriels M
Delvaux C
Salah F
Vaandering A
Geets X
Source :
Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology [Radiother Oncol] 2023 Jun; Vol. 183, pp. 109598. Date of Electronic Publication: 2023 Mar 09.
Publication Year :
2023

Abstract

Background and Purpose: Deep inspiration breath-hold (DIBH) protects critical organs-at-risk (OARs) for adjuvant breast radiotherapy. Guidance systems e.g. surface guided radiation therapy (SGRT) improve the positional breast reproducibility and stability during DIBH. In parallel, OARs sparing with DIBH is enhanced through different techniques e.g. prone position, continuous positive airway pressure (CPAP). By inducing repeated DIBH with the same level of positive pressure, mechanically-assisted and non-invasive ventilation (MANIV) could potentially combine these DIBH optimizations.<br />Materials and Methods: We conducted a randomized, open-label, multicenter and single-institution non-inferiority trial. Sixty-six patients eligible for adjuvant left whole-breast radiotherapy in supine position were equally assigned between mechanically-induced DIBH (MANIV-DIBH) and voluntary DIBH guided by SGRT (sDIBH). The co-primary endpoints were positional breast stability and reproducibility with a non-inferiority margin of 1 mm. Secondary endpoints were tolerance assessed daily via validated scales, treatment time, dose to OARs and their inter-fraction positional reproducibility.<br />Results: Differences between both arms for positional breast reproducibility and stability occurred at a sub-millimetric level (p < 0.001 for non-inferiority). The left anterior descending artery near-max dose (14,6 ± 12,0 Gy vs. 7,7 ± 7,1 Gy, p = 0,018) and mean dose (5,0 ± 3,5 Gy vs. 3,0 ± 2,0 Gy, p = 0,009) were improved with MANIV-DIBH. The same applied for the V <subscript>5Gy</subscript> of the left ventricle (2,4 ± 4,1 % vs. 0,8 ± 1,6 %, p = 0,001) as well as for the left lung V <subscript>20Gy</subscript> (11,4 ± 2,8 % vs. 9,7 ± 2,7 %, p = 0,019) and V <subscript>30Gy</subscript> (8,0 ± 2,6 % vs. 6,5 ± 2,3 %, p = 0,0018). Better heart's inter-fraction positional reproducibility was observed with MANIV-DIBH. Tolerance and treatment time were similar.<br />Conclusion: Mechanical ventilation provides the same target irradiation accuracy as with SGRT while better protecting and repositioning OARs.<br />Competing Interests: Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.<br /> (Copyright © 2023 Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
1879-0887
Volume :
183
Database :
MEDLINE
Journal :
Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology
Publication Type :
Academic Journal
Accession number :
36898583
Full Text :
https://doi.org/10.1016/j.radonc.2023.109598