Back to Search Start Over

Attenuated cardiac autonomic function in humans with high-affinity hemoglobin and compensatory polycythemia.

Authors :
Pruter WW
Klassen SA
Dominelli PB
Wiggins CC
Senefeld JW
Roy TK
Joyner MJ
Baker SE
Source :
American journal of physiology. Regulatory, integrative and comparative physiology [Am J Physiol Regul Integr Comp Physiol] 2023 May 01; Vol. 324 (5), pp. R625-R634. Date of Electronic Publication: 2023 Mar 06.
Publication Year :
2023

Abstract

During hypoxic exposure, humans with high-affinity hemoglobin (and compensatory polycythemia) have blunted increases in heart rate compared with healthy humans with typical oxyhemoglobin dissociation curves. This response may be associated with altered autonomic control of heart rate. Our hypothesis-generating study aimed to investigate cardiac baroreflex sensitivity and heart rate variability among nine humans with high-affinity hemoglobin [6 females, O <subscript>2</subscript> partial pressure at 50% [Formula: see text] (P <subscript>50</subscript> ) = 16 ± 1 mmHg] compared with 12 humans with typical affinity hemoglobin (6 F, P <subscript>50</subscript> = 26 ± 1 mmHg). Participants breathed normal room air for a 10-min baseline, followed by 20 min of isocapnic hypoxic exposure, designed to lower the arterial partial pressure O <subscript>2</subscript> ([Formula: see text]) to ∼50 mmHg. Beat-by-beat heart rate and arterial blood pressure were recorded. Data were averaged in 5-min periods throughout the hypoxia exposure, beginning with the last 5 min of baseline in normoxia. Spontaneous cardiac baroreflex sensitivity and heart rate variability were determined using the sequence method and the time and frequency domain analyses, respectively. Cardiac baroreflex sensitivity was lower in humans with high-affinity hemoglobin than controls at baseline and during isocapnic hypoxic exposure (normoxia: 7 ± 4 vs. 16 ± 10 ms/mmHg, hypoxia minutes 15-20: 4 ± 3 vs. 14 ± 11 ms/mmHg; group effect: P = 0.02, high-affinity hemoglobin vs. control, respectively). Heart rate variability calculated in both the time (standard deviation of the N-N interval) and frequency (low frequency) domains was lower in humans with high-affinity hemoglobin than in controls (all P < 0.05). Our data suggest that humans with high-affinity hemoglobin may have attenuated cardiac autonomic function.

Details

Language :
English
ISSN :
1522-1490
Volume :
324
Issue :
5
Database :
MEDLINE
Journal :
American journal of physiology. Regulatory, integrative and comparative physiology
Publication Type :
Academic Journal
Accession number :
36878486
Full Text :
https://doi.org/10.1152/ajpregu.00113.2022