Back to Search Start Over

Comparison between passive knee kinematics during surgery and active knee kinematics during walking: A preliminary study.

Authors :
Gasparutto X
Bonnefoy-Mazure A
Attias M
Dumas R
Armand S
Miozzari H
Source :
PloS one [PLoS One] 2023 Mar 06; Vol. 18 (3), pp. e0282517. Date of Electronic Publication: 2023 Mar 06 (Print Publication: 2023).
Publication Year :
2023

Abstract

Recovery of function is among a patient's main expectations when undergoing total knee arthroplasty (TKA). However, normal gait knee function is not always completely restored, which can affect patient satisfaction and quality of life. Computer-assisted surgery (CAS) allows surgeons to evaluate passive knee kinematics intra-operatively. Understanding associations between knee kinematics measured during surgery and during daily activities, such as walking, could help define criteria for success based on knee function and not only on the correct alignment of the implant or the leg. This preliminary study compared passive knee kinematics measured during surgery with active kinematics measured during walking. Eight patients underwent a treadmill gait analysis using the KneeKG™ system both before surgery and three months afterwards. Knee kinematics were measured during CAS both before and after TKA implantation. The anatomical axes of the KneeKG™ and CAS systems were homogenised using a two-level, multi-body kinematics optimisation with a kinematic chain based on the calibration measured during CAS. A Bland-Altman analysis was performed before and after TKA for adduction-abduction angle, internal-external rotation, and anterior-posterior displacement over the whole gait cycle, at the single stance phase and at the swing phase. Homogenising the anatomical axes between CAS and treadmill gait led to limited median bias and limits of agreement (post-surgery -0.6 ± 3.6 deg, -2.7 ± 3.6 deg, and -0.2 ± 2.4 mm for adduction-abduction, internal-external rotation and anterior-posterior displacement, respectively). At the individual level, correlations between the two systems were mostly weak (R2 < 0.3) over the whole gait cycle, indicating low kinematic consistency between the two measurements. However, correlations were better at the phase level, especially the swing phase. The multiple sources of differences did not enable us to conclude whether they came from anatomical and biomechanical differences or from measurement system errors.<br />Competing Interests: I have read the journal’s policy and the authors of this manuscript have the following competing interests: Hermes Miozzari is an associate editor for EFORT Open Reviews and a board member of Swiss Orthopaedics. Stéphane Armand is a member of the editorial board of EFORT Open Reviews. There are no competing interests associated with this research.<br /> (Copyright: © 2023 Gasparutto et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.)

Details

Language :
English
ISSN :
1932-6203
Volume :
18
Issue :
3
Database :
MEDLINE
Journal :
PloS one
Publication Type :
Academic Journal
Accession number :
36877708
Full Text :
https://doi.org/10.1371/journal.pone.0282517