Back to Search Start Over

Mechanical properties and accuracy of removable partial denture frameworks fabricated by digital and conventional techniques: A systematic review.

Authors :
Souza Curinga MR
Claudino Ribeiro AK
de Moraes SLD
do Egito Vasconcelos BC
da Fonte Porto Carreiro A
Pellizzer EP
Source :
The Journal of prosthetic dentistry [J Prosthet Dent] 2023 Mar 02. Date of Electronic Publication: 2023 Mar 02.
Publication Year :
2023
Publisher :
Ahead of Print

Abstract

Statement of Problem: Providing a removable partial denture (RPD) can be a complex, time-consuming, and error-prone procedure. Computer-aided design and computer-aided manufacturing (CAD-CAM) techniques have shown promising clinical outcomes; however, the influence of manufacturing techniques on the properties of RPD components is unclear.<br />Purpose: The purpose of this systematic review was to determine the accuracy and mechanical properties of RPD components fabricated with conventional and digital methods.<br />Material and Methods: This study followed the guidelines of the Preferred Reporting Items for Systematic Review and Meta-analyses (PRISMA) and was registered on the international prospective register of systematic reviews (PROSPERO) database (CRD42022353993). An electronic search was conducted on PubMed/MEDLINE, Scopus, Web of Science, and the Cochrane Library in August 2022. Only in vitro studies comparing the digital with the lost-wax casting technique were included. The quality of the studies was assessed by using the methodological index for nonrandomized studies (MINORS) scale.<br />Results: Of the 17 selected studies, 5 evaluated the accuracy of RPD components as well as the mechanical properties, 5 studies evaluated only the component accuracy, and another 7 evaluated only the mechanical properties. The accuracy was similar regardless of the technique, with discrepancies within clinically acceptable values (50 to 426.3 μm). The surface roughness was higher for 3D-printed clasps and lower for milled clasps (P<.05). The metal alloy significantly influenced the porosity, with the highest number of pores obtained by casting for Ti clasps and by rapid prototyping for Co-Cr clasps.<br />Conclusions: In vitro studies showed that the digital technique provided similar accuracy to that of the conventional technique within a clinically acceptable range. The manufacturing technique influenced the mechanical properties of RPD components.<br /> (Copyright © 2023 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1097-6841
Database :
MEDLINE
Journal :
The Journal of prosthetic dentistry
Publication Type :
Academic Journal
Accession number :
36870892
Full Text :
https://doi.org/10.1016/j.prosdent.2023.01.032