Back to Search
Start Over
Evaluation of calculation processes of apparent diffusion coefficient subtraction method (ASM) imaging.
- Source :
-
PloS one [PLoS One] 2023 Feb 27; Vol. 18 (2), pp. e0282462. Date of Electronic Publication: 2023 Feb 27 (Print Publication: 2023). - Publication Year :
- 2023
-
Abstract
- A number of restricted diffusion (RD) imaging techniques, such as diffusion kurtosis (DK) imaging and Q space imaging, have been developed and proven to be useful for the diagnosis of diseases, including cerebral gliomas and cerebrovascular infarction. In particular, apparent diffusion coefficient (ADC) subtraction method (ASM) imaging has become available recently as a novel RD imaging technique. ASM is based on the difference between the ADC values in an image pair of two ADC maps, ADC basic (ADCb) and ADC modify (ADCm), which are created from diffusion-weighted images taken using short and long effective diffusion times, respectively. The present study aimed to assess the potential of different types of ASM imaging by comparing them with DK imaging which is the gold-standard RD imaging technique. In the present basic study using both polyethylene glycol phantom and cell-containing bio-phantom, three different types of ASM images were created using different calculation processes. ASM/A is an image calculated by dividing the absolute difference between ADCb and ADCm by ADCb several times. By contrast, ASM/S is an image created by dividing the absolute difference between ADCb and ADCm by the standard deviation of ADCb several times. As for positive ASM/A image (PASM/A), the positive image, which was resultant after subtracting ADCb from ADCm, was divided by ADCb several times. A comparison was made between the types of ASM and DK images. The results showed the same tendency between ASM/A in addition to both ASM/S and PASM/A. By increasing the number of divisions by ADCb from three to five times, ASM/A images transformed from DK-mimicking to more RD-sensitive images compared with DK images. These observations suggest that ASM/A images may prove useful for future clinical applications in RD imaging protocols for the diagnosis of diseases.<br />Competing Interests: The authors have declared that no competing interests exist.<br /> (Copyright: © 2023 Barham et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.)
- Subjects :
- Diffusion
Phantoms, Imaging
Diffusion Tensor Imaging
Subtraction Technique
Subjects
Details
- Language :
- English
- ISSN :
- 1932-6203
- Volume :
- 18
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- PloS one
- Publication Type :
- Academic Journal
- Accession number :
- 36848353
- Full Text :
- https://doi.org/10.1371/journal.pone.0282462