Back to Search Start Over

Coherent mapping of atrial tachycardias in patients with congenital heart disease.

Authors :
Klehs S
Paech C
Bertagnolli L
Markel F
Dähnert I
Gebauer R
Source :
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology [Europace] 2023 Apr 15; Vol. 25 (4), pp. 1475-1481.
Publication Year :
2023

Abstract

Aims: Coherent mapping (CM) uses a new algorithm to identify critical conduction isthmuses of atrial tachycardias (ATs). We analysed our experience of ablation of AT in patients with congenital heart disease (CHD) with this new technology.<br />Methods and Results: All patients with CHD who had CM of AT using the high-density mapping PENTARAY™ catheter and three-dimensional electroanatomic mapping system Carto3 between June 2019 and June 2021 were included retrospectively (n = 27). As a control group, 27 patients with CHD and mapping of AT without CM between March 2016 and June 2019 were included. In total, 54 ablation procedures were performed in 42 patients [median age 35 (interquartile range, IQR 30-48) years] and 64 ATs were induced and mapped (thereof 50 AT intraatrial re-entrant tachycardia and 14 AT ectopic AT). The median procedure duration was 180 (120-214) min and median fluoroscopy time was 10 (5.2-14) min. Acute success was 100% (27/27) in the Coherence group and 74% (20/27) in the non-Coherence group (P = 0.01). During follow-up [median 26 (12-45) months], AT recurred in 28/54 patients, thereof 15 patients needed a re-ablation procedure. Log-rank test showed no difference in recurrence rate between the two groups (P = 0.29). Three minor complications occurred (5.5%).<br />Conclusion: Mapping of AT in patients with CHD using the PENTARAY™ mapping catheter and the CM algorithm led to excellent acute success. All ATs were possible to map and no complications related to the PENTARAY™ mapping catheter were observed. Thus, the use of the CM algorithm represents a promising tool in patients with CHD and complex AT.<br />Competing Interests: Conflict of interest: None declared.<br /> (© The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology.)

Details

Language :
English
ISSN :
1532-2092
Volume :
25
Issue :
4
Database :
MEDLINE
Journal :
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
Publication Type :
Academic Journal
Accession number :
36793240
Full Text :
https://doi.org/10.1093/europace/euad024