Back to Search Start Over

The use of dedicated long-axis views focused on the left atrium improves the accuracy of left atrial volumes and emptying fraction measured by cardiovascular magnetic resonance.

Authors :
Tondi L
Badano LP
Figliozzi S
Pica S
Torlasco C
Camporeale A
Florescu DR
Disabato G
Parati G
Lombardi M
Muraru D
Source :
Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance [J Cardiovasc Magn Reson] 2023 Feb 16; Vol. 25 (1), pp. 10. Date of Electronic Publication: 2023 Feb 16.
Publication Year :
2023

Abstract

Background: The use of apical views focused on the left atrium (LA) has improved the accuracy of LA volume evaluation by two-dimensional (2D) echocardiography. However, routine cardiovascular magnetic resonance (CMR) evaluation of LA volumes still uses standard 2- and 4-chamber cine images focused on the left ventricle (LV). To investigate the potential of LA-focused CMR cine images, we compared LA maximuml (LAVmax) and minimum (LAVmin) volumes, and emptying fraction (LAEF), calculated on both standard and LA-focused long-axis cine images, with LA volumes and LAEF obtained by short-axis cine stacks covering the LA. LA strain was also calculated and compared between standard and LA-focused images.<br />Methods: LA volumes and LAEF were obtained from 108 consecutive patients by applying the biplane area-length algorithm to both standard and LA-focused 2- and 4-chamber cine images. Manual segmentation of a short-axis cine stack covering the LA was used as the reference method. In addition, LA strain reservoir (εs), conduit (εe) and booster pump (εa) were calculated using CMR feature-tracking.<br />Results: Compared to the reference method, the standard approach significantly underestimated LA volumes (LAVmax: bias - 13 ml; LOA =  + 11, - 37 ml; LAVmax i: bias - 7 ml/m <superscript>2</superscript> ; LOA =  + 7, - 21 ml/m <superscript>2</superscript> ; LAVmin; bias - 10 ml, LOA: + 9, - 28 ml; LAVmin i: bias - 5 ml/m <superscript>2</superscript> , LOA: + 5, - 16 ml/m <superscript>2</superscript> ), and overestimated LA-EF (bias 5%, LOA: + 23, - 14%). Conversely, LA volumes (LAVmax: bias 0 ml; LOA: + 10, - 10 ml; LAVmax i: bias 0 ml/m <superscript>2</superscript> ; LOA: + 5, - 6 ml/m <superscript>2</superscript> ; LAVmin: bias - 2 ml; LOA: + 7, - 10 ml; LAVmin i: bias - 1 ml/m <superscript>2</superscript> ; LOA: + 3, - 5 ml/m <superscript>2</superscript> ) and LAEF (bias 2%, LOA: + 11, - 7%) by LA-focused cine images were similar to those measured using the reference method. LA volumes by LA-focused images were obtained faster than using the reference method (1.2 vs 4.5 min, p < 0.001). LA strain (εs: bias 7%, LOA = 25, - 11%; εe: bias 4%, LOA = 15, - 8%; εa: bias 3%, LOA = 14, - 8%) was significantly higher in standard vs. LA-focused images (p < 0.001).<br />Conclusion: LA volumes and LAEF measured using dedicated LA-focused long-axis cine images are more accurate than using standard LV-focused cine images. Moreover, LA strain is significantly lower in LA-focused vs. standard images.<br /> (© 2023. The Author(s).)

Details

Language :
English
ISSN :
1532-429X
Volume :
25
Issue :
1
Database :
MEDLINE
Journal :
Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
Publication Type :
Academic Journal
Accession number :
36793062
Full Text :
https://doi.org/10.1186/s12968-022-00905-w