Back to Search Start Over

Polypropylene composite hernia mesh with anti-adhesion layer composed of PVA hydrogel and liposomes drug delivery system.

Authors :
Wei D
Huang Y
Liang M
Ren P
Tao Y
Xu L
Zhang T
Ji Z
Zhang Q
Source :
Colloids and surfaces. B, Biointerfaces [Colloids Surf B Biointerfaces] 2023 Mar; Vol. 223, pp. 113159. Date of Electronic Publication: 2023 Jan 20.
Publication Year :
2023

Abstract

Polypropylene (PP) mesh has been widely used in hernia repair as prosthesis material owing to its excellent balanced biocompatibility and mechanical properties. However, abdominal adhesion between the visceral and PP mesh is still a major problem. Therefore, anti-adhesive PP mesh was designed with poly(vinyl alcohol) (PVA) hydrogel and liposomes drug delivery system. First, PVA hydrogel coating was formed on the surface of PP mesh with freezing-thawing processing cycles (FTP). Subsequently, the lyophilized PVA <subscript>10</subscript> -c-PP was immersed in rapamycin (RPM)-loaded liposome solution until swelling equilibrated to obtain the anti-adhesion mesh RPM@LPS/PVA <subscript>10</subscript> -c-PP. It was demonstrated that the hydrogel coating can stably fix on the surface of PP mesh even after immersed in PBS solution at 37 °C or 40 °C for up to 30 days. In vitro cell tests revealed the excellent cytocompatibility and the potential to inhibit cell adhesion of the modified PP mesh. Moreover, the anti-adhesive effects of the RPM@LPS/PVA <subscript>10</subscript> -c-PP mesh was evaluated through in vivo experiments. The RPM@LPS/PVA <subscript>10</subscript> -c-PP mesh exhibited less adhesion than original PP mesh throughout the duration of implantation. At 30 days, the adhesion score of RPM@LPS/PVA <subscript>10</subscript> -c-PP mesh was 1.37 ± 0.75, however the original PP was 3 ± 0.71. Furthermore, the results of H&E and Masson trichrome staining proved that the RPM@LPS/PVA <subscript>10</subscript> -c-PP mesh showed slighter inflammation response and significant looser fibrous tissue surrounded the PP filaments as compared to the native PP. The current findings manifested that this type of RPM@LPS/PVA <subscript>10</subscript> -c-PP might be a potential candidate for anti-adhesion treatment. DATA AVAILABILITY: Data will be made available on request.<br />Competing Interests: Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.<br /> (Copyright © 2023 Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
1873-4367
Volume :
223
Database :
MEDLINE
Journal :
Colloids and surfaces. B, Biointerfaces
Publication Type :
Academic Journal
Accession number :
36736174
Full Text :
https://doi.org/10.1016/j.colsurfb.2023.113159