Back to Search Start Over

Agreement of a Novel Artificial Intelligence Software With Optical Coherence Tomography and Manual Grading of the Optic Disc in Glaucoma.

Authors :
Shroff S
Rao DP
Savoy FM
Shruthi S
Hsu CK
Pradhan ZS
Jayasree PV
Sivaraman A
Sengupta S
Shetty R
Rao HL
Source :
Journal of glaucoma [J Glaucoma] 2023 Apr 01; Vol. 32 (4), pp. 280-286. Date of Electronic Publication: 2022 Nov 28.
Publication Year :
2023

Abstract

Prcis: The offline artificial intelligence (AI) on a smartphone-based fundus camera shows good agreement and correlation with the vertical cup-to-disc ratio (vCDR) from the spectral-domain optical coherence tomography (SD-OCT) and manual grading by experts.<br />Purpose: The purpose of this study is to assess the agreement of vCDR measured by a new AI software from optic disc images obtained using a validated smartphone-based imaging device, with SD-OCT vCDR measurements, and manual grading by experts on a stereoscopic fundus camera.<br />Methods: In a prospective, cross-sectional study, participants above 18 years (Glaucoma and normal) underwent a dilated fundus evaluation, followed by optic disc imaging including a 42-degree monoscopic disc-centered image (Remidio NM-FOP-10), a 30-degree stereoscopic disc-centered image (Kowa nonmyd WX-3D desktop fundus camera), and disc analysis (Cirrus SD-OCT). Remidio FOP images were analyzed for vCDR using the new AI software, and Kowa stereoscopic images were manually graded by 3 fellowship-trained glaucoma specialists.<br />Results: We included 473 eyes of 244 participants. The vCDR values from the new AI software showed strong agreement with SD-OCT measurements [95% limits of agreement (LoA)=-0.13 to 0.16]. The agreement with SD-OCT was marginally better in eyes with higher vCDR (95% LoA=-0.15 to 0.12 for vCDR>0.8). Interclass correlation coefficient was 0.90 (95% CI, 0.88-0.91). The vCDR values from AI software showed a good correlation with the manual segmentation by experts (interclass correlation coefficient=0.89, 95% CI, 0.87-0.91) on stereoscopic images (95% LoA=-0.18 to 0.11) with agreement better for eyes with vCDR>0.8 (LoA=-0.12 to 0.08).<br />Conclusions: The new AI software vCDR measurements had an excellent agreement and correlation with the SD-OCT and manual grading. The ability of the Medios AI to work offline, without requiring cloud-based inferencing, is an added advantage.<br />Competing Interests: Disclosure: D.P.R., F.M.S., C.K.H., and A.S. are employees of Remidio Innovative Solutions. H.L.R is a consultant for Santen, Allergan, and Pfizer. The remaining authors declare no conflict of interest.<br /> (Copyright © 2022 Wolters Kluwer Health, Inc. All rights reserved.)

Details

Language :
English
ISSN :
1536-481X
Volume :
32
Issue :
4
Database :
MEDLINE
Journal :
Journal of glaucoma
Publication Type :
Academic Journal
Accession number :
36730188
Full Text :
https://doi.org/10.1097/IJG.0000000000002147