Back to Search
Start Over
Modification of bimetal Zn/ Mg MOF with nanoparticles Fe 3 O 4 and Fe 3 O 4 @SiO 2 , investigation of the peroxidase-like activity of these compounds by calorimetry and fluorimetry methods.
- Source :
-
Heliyon [Heliyon] 2023 Jan 07; Vol. 9 (2), pp. e12866. Date of Electronic Publication: 2023 Jan 07 (Print Publication: 2023). - Publication Year :
- 2023
-
Abstract
- In this article; the bimetal metal-organic framework Zn/Mg (Zn/Mg MOF) is synthesized. Then Zn/Mg MOF bimetal was combined with Fe <subscript>3</subscript> O <subscript>4</subscript> and Fe <subscript>3</subscript> O <subscript>4</subscript> @SiO <subscript>2</subscript> , and composites of Fe <subscript>3</subscript> O <subscript>4</subscript> @ SiO <subscript>2</subscript> /MOF/Dextrin, Fe <subscript>3</subscript> O <subscript>4</subscript> @SiO <subscript>2</subscript> /MOF, Fe <subscript>3</subscript> O <subscript>4</subscript> @MOF/Dextrin and Fe <subscript>3</subscript> O <subscript>4</subscript> @MOF made. The peroxidase-like activity of these compounds was investigated and compared by calorimetric Resazurin (Rz) and O-phenylenediamine (OPD); (Rz-H <subscript>2</subscript> O <subscript>2</subscript> , OPD-H <subscript>2</subscript> O <subscript>2</subscript> ) and fluorimetric Rz and terephtalic acid (TA); (Rz-H <subscript>2</subscript> O <subscript>2</subscript> , TA-H <subscript>2</subscript> O <subscript>2</subscript> ). The Fe <subscript>3</subscript> O <subscript>4</subscript> @ MOF/Dextrin composite has the highest peroxidase-like activity. The effect factors (amount of pH (6), the values of TA (1.37 mM), H <subscript>2</subscript> O <subscript>2</subscript> (0.025 mM), reaction time (8.15 min), and amount of Composite (116.67 mg)) to increase the catalytic activity of Fe <subscript>3</subscript> O <subscript>4</subscript> @ MOF/Dextrin measured by chemometrics method. The most suitable linear range of the calibration curve by the TA-H <subscript>2</subscript> O <subscript>2</subscript> -Composite fluorimetric method is 1-600 μg L <superscript>-1</superscript> , and the detection limit is 2.27 μg L <superscript>-1</superscript> . The relative standard deviation (RSD%) for measuring concentration atropine 1 μg L <superscript>-1</superscript> (n = 6) is 1.18%. Finally, from this system for measuring atropine extracted by the Liquid-liquid extraction (LLE) method in two types of plants, D. Innoxia north and west and D. stramonium north and west of Iran (118.25 μg L <superscript>-1</superscript> , 79.80 μg L <superscript>-1</superscript> ) and (18.477 μg L <superscript>-1</superscript> , 9.27 μg L <superscript>-1</superscript> ) used, respectively.<br /> (© 2023 The Authors.)
Details
- Language :
- English
- ISSN :
- 2405-8440
- Volume :
- 9
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- Heliyon
- Publication Type :
- Academic Journal
- Accession number :
- 36718154
- Full Text :
- https://doi.org/10.1016/j.heliyon.2023.e12866