Back to Search Start Over

Volatile organic compounds (VOC) in homes associated with asthma and lung function among adults in Northern Europe.

Authors :
Wang J
Janson C
Gislason T
Gunnbjörnsdottir M
Jogi R
Orru H
Norbäck D
Source :
Environmental pollution (Barking, Essex : 1987) [Environ Pollut] 2023 Mar 15; Vol. 321, pp. 121103. Date of Electronic Publication: 2023 Jan 21.
Publication Year :
2023

Abstract

Associations between measured specific VOC reported to be associated with dampness and microbial growth in dwellings and asthma, lung function were investigated in 159 adults (one adult/home) from three North European cities (Reykjavik, Uppsala and Tartu). Spirometry was performed and forced vital capacity (FVC), forced expiratory volume in 1 s (FEV <subscript>1</subscript> ) and FEV <subscript>1</subscript> /FVC were measured. Among 159 participants, 58% were females, 24.5% atopics, 25.8% current smokers and 41% reported dampness or mold at home. Dimethyl disulphide (p = 0.004), ethyl isobutyrate (p = 0.021) and ethyl 2-methylbutyrate (p = 0.035) were associated with asthma. Isobutanol (p = 0.043), 3-methyl-1-butanol (p = 0.020), 2-hexanone (p = 0.033), 1-octen-3-ol (p = 0.027), 2-methyl-1-butanol (p = 0.022) and 2-ethyl-1-hexanol (p = 0.045) were associated with lower FEV <subscript>1</subscript> . Isobutanol (p = 0.004), 3-methyl-1-butanol (p = 0.001), 2-heptanone (p = 0.047) and 2-methyl-1-butanol (p = 0.002) were associated with lower FEV <subscript>1</subscript> /FVC. The association between dimethyl disulphide and asthma was more pronounced in females (p for interaction 0.099). The association between 1-butanol and lower FEV <subscript>1</subscript> was more pronounced in males (p for interaction 0.046). The associations between 3-octanone (p for interaction 0.064), 2-ethyl-1-hexanol (p for interaction 0.049) and lower FEV <subscript>1</subscript> , and between 2-heptanone (p for interaction 0.021), 3-octanone (p for interaction 0.008) and lower FEV <subscript>1</subscript> /FVC were stronger in homes with dampness/mold. Factor analysis identified one VOC factor related to asthma and two VOC factors related to lower lung function. Increased air concentrations of 2-heptanone, ethyl 2-methylbutyrate and ethyl isobutyrate were related to prescence of certain mold species (Aspergillus sp., Cladosporum sp. and Penicillium sp.) or building dampness. Some VOC were associated with type of dwelling, building age and pet keeping. In conclusion, some VOC reported to be associated with dampness and microbial growth can be associated with asthma and lower lung function in adults. Associations between these VOC and respiratory illness can be stronger in homes with dampness/mold. There can be gender differences in respiratory health effects when exposed to indoor VOC.<br />Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.<br /> (Copyright © 2023 The Authors. Published by Elsevier Ltd.. All rights reserved.)

Details

Language :
English
ISSN :
1873-6424
Volume :
321
Database :
MEDLINE
Journal :
Environmental pollution (Barking, Essex : 1987)
Publication Type :
Academic Journal
Accession number :
36690293
Full Text :
https://doi.org/10.1016/j.envpol.2023.121103