Back to Search Start Over

[Clinical application of targeted sealing with high viscosity bone cement and secondary injection of low viscosity bone cement in vertebroplasty].

Authors :
Liu CZ
Jia BX
Gao XQ
Li WY
Liu AG
Ren CH
Source :
Zhongguo gu shang = China journal of orthopaedics and traumatology [Zhongguo Gu Shang] 2023 Jan 25; Vol. 36 (1), pp. 38-42.
Publication Year :
2023

Abstract

Objective: To observe the clinical efficacy of targeted sealing with high viscosity bone cement and secondary injection of low viscosity bone cement in the treatment of OVCFs patients with the fracture lines involved vertebral body margin.<br />Methods: The elderly patients who underwent vertebroplasty for osteoporotic vertebral compression fractures from January 2019 to September 2021 were selected as the screening objects. Through relevant standards and further CT examination, 56 patients with fracture lines involving the anterior wall or upper and lower endplates of the vertebral body were selected for the study. There were 21 males and 35 females, aged from 67 to 89 years old with an average of (76.58±9.68) years. All 56 patients underwent secondary injection of bone cement during operation. Only a small amount of high viscosity cement was targeted to seal the edge of the vertebral body for the first time, and low viscosity cement was injected to the vertebral bodies during second bolus with well-distributed. The operation time, bone cement volume and bone cement leakage were recorded, and the pain relief was evaluated by visual analogue scale (VAS).<br />Results: All patients were followed up for more than 3 months and the surgeries were successfully complete. The operation time was (50.41±10.30) min and the bone cement volume was (3.64±1.29) ml. The preoperative VAS was (7.21±2.41) points, which decreased significantly to (2.81±0.97) points 3 days after operation( P <0.05). Among the 56 patients, 2 cases(3.57%) had bone cement leakage, 1 case leaked to the paravertebral vein, and 1 case slightly bulged to the paravertebral through the crack when plugging the vertebral crack. Both patients had no obvious clinical symptoms.<br />Conclusion: In vertebroplasty surgery, targeted sealing of high viscosity bone cement and secondary injection of low viscosity bone cement can reduce intraoperative bone cement leakage and improve the safety of operation.

Details

Language :
Chinese
ISSN :
1003-0034
Volume :
36
Issue :
1
Database :
MEDLINE
Journal :
Zhongguo gu shang = China journal of orthopaedics and traumatology
Publication Type :
Academic Journal
Accession number :
36653004
Full Text :
https://doi.org/10.12200/j.issn.1003-0034.2023.01.007