Bicolor K-edge spectral photon-counting CT imaging for the diagnosis of thoracic endoleaks: A dynamic phantom study.
- Source :
-
Diagnostic and interventional imaging [Diagn Interv Imaging] 2023 May; Vol. 104 (5), pp. 235-242. Date of Electronic Publication: 2023 Jan 15. - Publication Year :
- 2023
-
Abstract
- Purpose: The purpose of this study was to investigate the feasibility of identifying and characterizing the three most common types of endoleaks within a thoracic aorta aneurysm model using bicolor K-edge imaging with a spectral photon-counting computing tomography (SPCCT) system in combination with a biphasic contrast agent injection.<br />Materials and Methods: Three types of thoracic endoleaks (type 1, 2 and 3) were created in a dynamic anthropomorphic thoracic aorta phantom. Protocol consisted in an injection of an iodinated contrast material followed 80 seconds after an injection of a gadolinium-based contrast agent (GBCA). The phantom was scanned using a clinical prototype SPCCT during bicolor phase imaging consisting in an early distribution of GBCA and a late distribution of iodine. Conventional and spectral images were reconstructed for differentiating between the contrast agents and measuring their respective attenuation values and concentrations inside and outside the stent graft.<br />Results: Conventional images failed to provide specific dynamic imaging contrast agents in the aneurysmal sac and outside the stent graft while spectral images differentiated their specific distribution. In type 1 and 3 thoracic endoleaks, GBCA concentration was measured outside the stent graft at 6.1 ± 3.7 (standard deviation [SD]) mg/mL and 6.0 ± 4.0 (SD) mg/mL, respectively, in favor of an early blood flow. In type 2 thoracic endoleak, iodine was measured outside the stent graft at 24.3 ± 5.5 (SD) mg/mL in favor of a late blood flow in the aneurysmal sac.<br />Conclusion: Bicolor K-edge imaging enabled SPCCT allows a bicolor characterization of thoracic aorta endoleaks in a single acquisition in combination with a biphasic contrast agent injection.<br />Competing Interests: Declaration of Competing Interest The authors has no conflicts of interest to disclose in relation with this article.<br /> (Copyright © 2023 The Authors. Published by Elsevier Masson SAS.. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 2211-5684
- Volume :
- 104
- Issue :
- 5
- Database :
- MEDLINE
- Journal :
- Diagnostic and interventional imaging
- Publication Type :
- Academic Journal
- Accession number :
- 36646587
- Full Text :
- https://doi.org/10.1016/j.diii.2022.12.003