Back to Search Start Over

Prospective Multicenter Diagnostic Performance of Technologist-Performed Screening Breast Ultrasound After Tomosynthesis in Women With Dense Breasts (the DBTUST).

Authors :
Berg WA
Zuley ML
Chang TS
Gizienski TA
Chough DM
Böhm-Vélez M
Sharek DE
Straka MR
Hakim CM
Hartman JY
Harnist KS
Tyma CS
Kelly AE
Waheed U
Houshmand G
Nair BE
Shinde DD
Lu AH
Bandos AI
Berg JM
Lettiere NB
Ganott MA
Source :
Journal of clinical oncology : official journal of the American Society of Clinical Oncology [J Clin Oncol] 2023 May 01; Vol. 41 (13), pp. 2403-2415. Date of Electronic Publication: 2023 Jan 10.
Publication Year :
2023

Abstract

Purpose: To assess diagnostic performance of digital breast tomosynthesis (DBT) alone or combined with technologist-performed handheld screening ultrasound (US) in women with dense breasts.<br />Methods: In an institutional review board-approved, Health Insurance Portability and Accountability Act-compliant multicenter protocol in western Pennsylvania, 6,179 women consented to three rounds of annual screening, interpreted by two radiologist observers, and had appropriate follow-up. Primary analysis was based on first observer results.<br />Results: Mean participant age was 54.8 years (range, 40-75 years). Across 17,552 screens, there were 126 cancer events in 125 women (7.2/1,000; 95% CI, 5.9 to 8.4). In year 1, DBT-alone cancer yield was 5.0/1,000, and of DBT+US, 6.3/1,000, difference 1.3/1,000 (95% CI, 0.3 to 2.1; P = .005). In years 2 + 3, DBT cancer yield was 4.9/1,000, and of DBT+US, 5.9/1,000, difference 1.0/1,000 (95% CI, 0.4 to 1.5; P < .001). False-positive rate increased from 7.0% for DBT in year 1 to 11.5% for DBT+US and from 5.9% for DBT in year 2 + 3 to 9.7% for DBT+US ( P < .001 for both). Nine cancers were seen only by double reading DBT and one by double reading US. Ten interval cancers (0.6/1,000 [95% CI, 0.2 to 0.9]) were identified. Despite reduction in specificity, addition of US improved receiver operating characteristic curves, with area under receiver operating characteristic curve increasing from 0.83 for DBT alone to 0.92 for DBT+US in year 1 ( P = .01), with smaller improvements in subsequent years. Of 6,179 women, across all 3 years, 172/6,179 (2.8%) unique women had a false-positive biopsy because of DBT as did another 230/6,179 (3.7%) women because of US ( P < .001).<br />Conclusion: Overall added cancer detection rate of US screening after DBT was modest at 19/17,552 (1.1/1,000; CI, 0.5- to 1.6) screens but potentially overcomes substantial increases in false-positive recalls and benign biopsies.

Details

Language :
English
ISSN :
1527-7755
Volume :
41
Issue :
13
Database :
MEDLINE
Journal :
Journal of clinical oncology : official journal of the American Society of Clinical Oncology
Publication Type :
Academic Journal
Accession number :
36626696
Full Text :
https://doi.org/10.1200/JCO.22.01445