Back to Search Start Over

Safe Follow-Up after Endovascular Aortic Repair with Unenhanced MRI: The SAFEVAR Study.

Authors :
Secchi F
Capra D
Monti CB
Mobini N
Ortiz MDMG
Trimarchi S
Mazzaccaro D
Righini P
Nano G
Sardanelli F
Source :
Diagnostics (Basel, Switzerland) [Diagnostics (Basel)] 2022 Dec 21; Vol. 13 (1). Date of Electronic Publication: 2022 Dec 21.
Publication Year :
2022

Abstract

We aimed to investigate whether unenhanced magnetic resonance imaging (MRI) could represent a safe and highly sensitive tool for endoleak screening in patients treated with endovascular aneurysm repair (EVAR) using computed tomography angiography (CTA) as a reference standard. Patients who underwent CTA for EVAR follow-up at our institution were prospectively enrolled. All MRI examinations were performed with a 1.5 T unit. The true-FISP and HASTE sequences of the MRI scans were assessed for the presence of hyperintensity within the aneurysm sac outside the graft, whereas phase-contrast through-plane sequences were used for blood flow quantification. We included 45 patients, 5 (11%) of whom were female. The median age was 73 years (IQR 68−78 years). Among our patients, 19 (42%) were positive for endoleaks at CTA, of whom 13 (68%) had type II endoleaks and 6 (32%) had type I endoleaks. There were no significant differences in age, sex, aneurysm type, prosthesis type, or contrast-to-noise ratio between hyperintensity and thrombus between patients with and without endoleaks (p > 0.300). The combined evaluation of true-FISP and HASTE yielded 100% sensitivity (95% CI: 79−100%) and 19% specificity (95% CI: 7−40%). Patients with a positive CTA had a median thrombus flow of 0.06 L/min (IQR 0.03−0.23 L/min), significantly greater than that of patients with a negative CTA (p = 0.007). Setting a threshold at 0.01 L/min, our MRI protocol yielded 100% sensitivity, 56% specificity, and an AUC of 0.76 (95% CI 0.60−0.91). In conclusion, unenhanced MRI has perfect sensitivity for endoleak detection, although with subpar specificity that could be improved with phase-contrast flow analysis.<br />Competing Interests: Caterina B. Monti has received travel support from Bracco. F. Sardanelli has received research grants from and is a member of the speakers’ bureau and of the advisory group for General Electric, Bayer, and Bracco. The other authors of this manuscript declare no relationships with any companies whose products or services may be related to the subject matter of the article.

Details

Language :
English
ISSN :
2075-4418
Volume :
13
Issue :
1
Database :
MEDLINE
Journal :
Diagnostics (Basel, Switzerland)
Publication Type :
Academic Journal
Accession number :
36611311
Full Text :
https://doi.org/10.3390/diagnostics13010020