Added value of semi-quantitative analysis of [18F]FDG PET/CT for the diagnosis of device-related infections in patients with a left ventricular assist device.

Authors :
Ten Hove D
Wahadat AR
Slart RHJA
Wouthuyzen-Bakker M
Mecozzi G
Damman K
Witteveen H
Caliskan K
Manintveld OC
Sinha B
Budde RPJ
Glaudemans AWJM
Source :
European heart journal. Cardiovascular Imaging [Eur Heart J Cardiovasc Imaging] 2023 May 31; Vol. 24 (6), pp. 819-828.
Publication Year :
2023

Abstract

Aims: Left ventricular assist devices (LVADs) improve quality of life and survival in patients with advanced heart failure, but device-related infections (DRIs) remain cumbersome. We evaluated the diagnostic capability of [18F]FDG PET/CT, factors affecting its accuracy, and the additive value of semi-quantitative analysis for the diagnosis of DRI.<br />Methods and Results: LVAD recipients undergoing [18F]FDG PET/CT between 2012 and 2020 for suspected DRI were retrospectively included. [18F]FDG PET/CT was performed and evaluated in accordance with EANM guidelines. The final diagnosis of DRI, based on multidisciplinary consensus and findings during surgery, whenever performed, was used as the reference for diagnosis. 41 patients were evaluated for 59 episodes of suspected DRI. The clinical evaluation established driveline infection in 32 (55%) episodes, central device infection in 6 (11%), and combined infection in 2 (4%). Visual analysis of [18F]FDG PET/CT achieved a sensitivity and specificity for driveline infections of 0.79 and 0.71, respectively, whereas semi-quantitative analysis achieved a sensitivity and specificity of 0.94 and 0.83, respectively. For central device component infection, visual analysis of [18F]FDG PET/CT achieved a sensitivity and specificity of 0.75 and 0.60, respectively. Semi-quantitative analysis using SUVratio achieved a sensitivity and specificity of 1.0 and 0.8, respectively. The increase of specificity for central component infection was statistically significant (P = 0.05).<br />Conclusions: [18F]FDG PET/CT reliably predicts the presence of DRI in LVAD recipients. Semi-quantitative analysis may increase the specificity of [18F]FDG PET/CT for the analysis of central device component infection and should be considered in equivocal cases after visual analysis.<br />Competing Interests: Conflict of interest: K.D. reports speaker fees from Abbott, manufacturer of HMII and HM3 LVAD. All other authors declare no potential conflict of interest.<br /> (© The Author(s) 2022. Published by Oxford University Press on behalf of the European Society of Cardiology.)

Details

Language :
English
ISSN :
2047-2412
Volume :
24
Issue :
6
Database :
MEDLINE
Journal :
European heart journal. Cardiovascular Imaging
Publication Type :
Academic Journal
Accession number :
36573930
Full Text :
https://doi.org/10.1093/ehjci/jeac260