Direct Cementation of Dual Mobility Cups Into the Bony Acetabulum in Primary Total Hip Arthroplasty: Clinical and Radiographic Outcomes at a Minimum 5-Year Follow-Up.

Authors :
Antoniadis A
Wegrzyn J
Source :
The Journal of arthroplasty [J Arthroplasty] 2023 Jun; Vol. 38 (6), pp. 1120-1125. Date of Electronic Publication: 2022 Dec 22.
Publication Year :
2023

Abstract

Background: Cemented dual mobility cups (DMCs) are commonly used in combination with acetabular reinforcement devices. Indeed, according to literature, direct cementation of metal-backed acetabular components into the bony acetabulum remains controversial as this technique is potentially associated with increased rates of aseptic loosening. Therefore, this study aimed to evaluate the clinical and radiographic outcomes of DMC cemented into the bony acetabulum in primary total hip arthroplasty (THA).<br />Methods: A total of 49 THA (48 patients, mean age 78 years [range, 51 to 91]) performed with direct cementation of a DMC into the bony acetabulum were prospectively included in our total joint registry and retrospectively reviewed. The clinical outcome was assessed using the Harris hip score (HHS). The radiographic outcome included measurement of component positioning and occurrence and progression of demarcation around the cemented DMC. Complications were reported with a particular attention to cemented fixation failure and aseptic loosening.<br />Results: At a 7-year mean follow-up (range, 5 to 8), the pre-to postoperative HHS improved from 47 (range, 30 to 58) to 92 points (range, 80 to 98) (P < .01). Nonprogressive and focalized demarcations were observed in 7 THA (14%). Importantly, no progressive demarcation or DMC aseptic loosening was observed.<br />Conclusion: Direct cementation of DMC into the bony acetabulum ensured a stable fixation with no progressive demarcation or aseptic loosening at midterm follow-up. Therefore, this technique can be selectively considered in primary THA, especially in elderly or frail patients to avoid potential mechanical failure of press-fit fixation due to altered bone quality or additional morbidity related to the use of acetabular reinforcement devices.<br /> (Copyright © 2022 The Author(s). Published by Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1532-8406
Volume :
38
Issue :
6
Database :
MEDLINE
Journal :
The Journal of arthroplasty
Publication Type :
Academic Journal
Accession number :
36566998
Full Text :
https://doi.org/10.1016/j.arth.2022.12.031