Evaluating the Impact of Applying Personal Glucose Targets in a Closed-Loop System for People With Type 1 Diabetes.

Authors :
Fattah M
Boughton CK
Ware J
Allen JM
Hartnell S
Willinska ME
Thankamony A
de Beaufort C
Campbell FM
Fröhlich-Reiterer E
Hofer SE
Kapellen TM
Rami-Merhar B
Ghatak A
Randell TL
Besser REJ
Elleri D
Trevelyan N
Denvir Md L
Davis N
Bally L
Thabit H
Leelarathna L
Evans ML
Mader JK
Hovorka R
Source :
Journal of diabetes science and technology [J Diabetes Sci Technol] 2024 May; Vol. 18 (3), pp. 695-700. Date of Electronic Publication: 2022 Dec 20.
Publication Year :
2024

Abstract

Background: CamAPS FX is a hybrid closed-loop smartphone app used to manage type one diabetes. The closed-loop algorithm has a default target glucose of 5.8 mmol/L (104.5 mg/dL), but users can select personal glucose targets (adjustable between 4.4 mmol/L and 11.0 mmol/L [79 mg/dL and 198 mg/dL, respectively]).<br />Method: In this post-hoc analysis, we evaluated the impact of personal glucose targets on glycemic control using data from participants in five randomized controlled trials.<br />Results: Personal glucose targets were widely used, with 20.3% of all days in the data set having a target outside the default target bin (5.5-6.0 mmol/L [99-108 mg/dL]). Personal glucose targets >6.5 mmol/L (117 mg/dL) were associated with significantly less time in target range (3.9-10.0 mmol/L [70-180 mg/dL]; 6.5-7.0 mmol/L [117-126 mg/dL]: mean difference = -3.2 percentage points [95% CI: -5.3 to -1.2; P < .001]; 7.0-7.5 mmol/L [126-135 mg/dL]: -10.8 percentage points [95% CI: -14.1 to -7.6; P < .001]). Personal targets >6.5 mmol/L (117 mg/dL) were associated with significantly lower time (<3.9 mmol/L [<70 mg/dL]; 6.5-7.0 mmol/L [117-126 mg/dL]: -1.85 percentage points [95% CI: -2.37 to -1.34; P < .001]; 7.0-7.5 mmol/L [126-135 mg/dL]: -2.68 percentage points [95% CI: -3.49 to -1.86; P < .001]).<br />Conclusions: Discrete study populations showed differences in glucose control when applying similar personal targets.<br />Competing Interests: Declaration of Conflicting InterestsThe author(s) declared the following potential conflicts of interest with respect to the research, authorship, and/or publication of this article: C.K.B. has received consulting fees from CamDiab and speaker honoraria from Ypsomed. J.W. has received speaker honoraria from Ypsomed. J.M.A. has received consulting fees from CamDiab. S.H. serves as a member of Sigma (Dexcom) and Medtronic advisory boards; is a consultant for CamDiab and a director of Ask Diabetes Ltd., providing training and research support in healthcare settings; and reports having received training honoraria from Medtronic, Sanofi, and Ypsomed. M.E.W. reports receiving license fees from B. Braun, patents related to closed-loop systems, and being a consultant at CamDiab. C.d.B. reports having received speaker honoraria from Medtronic and has served on the EU psychology e-learning board of Medtronic. E.F.-R. reports having received speaker honoraria from Medtronic, Eli Lilly and Company, Novo Nordisk, and Sanofi and serving on the advisory board for Eli Lilly and Company. S.E.H. has received speaker honoraria from Medtronic, Eli Lilly, Ypsomed, and Insulet. T.M.K. reports having received speaker honoraria from Eli Lilly, Merck Serono, and Novo Nordisk. B.R.-M. has received speaker honoraria from Abbott Diabetes Care, Eli Lilly, Medtronic, Novo Nordisk, Roche Diabetes Care, Sanofi, and Menarini and has been on the advisory boards of Eli Lilly, Roche Diabetes Care, and Abbott Diabetes Care. T.L.R. has received consultancy fees from Abbott Diabetes Care and speaker honoraria from Novo Nordisk. R.E.J.B. reports having received speaking honoraria from Eli Lilly and Springer Healthcare and sits as an unpaid member of the Novo Nordisk UK Research Foundation grant and selection committee. L.D. has received honoraria for taking part in an Interactive Advisory and Advocacy Forum on CGM Use in Pediatric Clinical Practice from Dexcom and has received conference fees from Novo Nordisk. H.T. reports having received research support from Dexcom and speaker honoraria from Eli Lilly and Dexcom. L.L. reports having received speaker honoraria from Animas, Abbott, Insulet, Medtronic, Novo Nordisk, Roche, and Sanofi; was on advisory panels for Animas, Abbott, Novo Nordisk, Dexcom, Medtronic, Sanofi, and Roche; and received research support from Novo Nordisk and Dexcom. M.L.E. reports having received speaker honoraria from Eli Lilly and Company, Novo Nordisk, Abbott Diabetes Care, Medtronic, AstraZeneca, and Ypsomed and acting on advisory boards for Medtronic, Novo Nordisk, Zucara Therapeutics, Pila Pharma, and Abbott Diabetes Care. J.K.M. is a member of the advisory boards of Abbott Diabetes Care, BD, Boehringer Ingelheim, Eli Lilly and Company, Medtronic, Novo Nordisk AS, Prediktor A/S, Roche Diabetes Care, and Sanofi; received speaker honoraria from Abbott Diabetes Care, AstraZeneca, Dexcom, Eli Lilly and Company, Menarini Diagnostics, Novo Nordisk A/S, Roche Diabetes Care, Servier, and Ypsomed; and is a cofounder and shareholder of decide Clinical Software Ltd. R.H. reports having received speaker honoraria from Eli Lilly and Company, Dexcom, and Novo Nordisk; receiving license fees from Medtronic; receiving patents related to closed-loop systems; and being the director at CamDiab. M.F., A.T., F.M.C., A.G., D.E., N.T., N.D., and L.B. have no conflict of interest to disclose.

Details

Language :
English
ISSN :
1932-2968
Volume :
18
Issue :
3
Database :
MEDLINE
Journal :
Journal of diabetes science and technology
Publication Type :
Academic Journal
Accession number :
36540007
Full Text :