Back to Search Start Over

Three-year follow-up of aortic arch endovascular stent grafting with the Nexus device: results from a prospective multicentre study.

Authors :
D'Onofrio A
Lachat M
Mangialardi N
Antonello M
Schelzig H
Chaykovska L
Hill A
Holden A
Lindsay T
Ten Tan K
Orrico M
Ronchey S
Greener GE
Hayes P
Lorenzoni G
Gerosa G
Planer D
Source :
European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery [Eur J Cardiothorac Surg] 2022 Dec 02; Vol. 63 (1).
Publication Year :
2022

Abstract

Objectives: Endovascular aortic arch stent grafting with branched devices has shown initial promising results. The aim of this prospective, multicentre study was to evaluate 3-year outcomes of aortic arch stent grafting with NEXUS® Aortic Arch Stent Graft System (Nexus), a single-branch, bi-modular, off-the-shelf aortic arch stent graft system in high-risk patients.<br />Methods: Patients treated with Nexus, either under the feasibility clinical study or as compassionate use procedures in 5 centres, were included in this study. The primary end point was overall survival. The secondary end points included the incidence of procedure-related unplanned intervention, stroke, paraplegia and endoleak. Clinical and radiologic follow-up was performed at each study site at 30 days, 6 months and on a yearly basis thereafter up to 3 years postoperatively.<br />Results: We analysed data from a total of 28 patients. The overall median follow-up was 1132 (interquartile range: 809-1537). There were no device or procedure-related deaths between 1 and 3 years. Overall survival at 1 and 3 years was 89% and 71%, respectively. The cumulative incidence of unplanned reintervention at 1 and 3 years was 11% and 29%, respectively. There were no reports of stroke, paraplegia, aneurysm rupture, myocardial infarction or new aortic valve insufficiency. In this study's 1-3 year follow-up period, 1 type Ib (4%), 1 type II (4%) and 2 type III (8%; between Nexus' distal end and Thoracic endovascular aortic repair (TEVAR) extensions) endoleak were detected.<br />Conclusions: Endovascular aortic arch exclusion with the single-branch, off-the-shelf Nexus system provides promising clinical and radiologic results at 3-year follow-up in a high-risk patient cohort.<br /> (© The Author(s) 2022. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.)

Details

Language :
English
ISSN :
1873-734X
Volume :
63
Issue :
1
Database :
MEDLINE
Journal :
European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
Publication Type :
Academic Journal
Accession number :
36484696
Full Text :
https://doi.org/10.1093/ejcts/ezac561