Back to Search
Start Over
Three-year follow-up of aortic arch endovascular stent grafting with the Nexus device: results from a prospective multicentre study.
- Source :
-
European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery [Eur J Cardiothorac Surg] 2022 Dec 02; Vol. 63 (1). - Publication Year :
- 2022
-
Abstract
- Objectives: Endovascular aortic arch stent grafting with branched devices has shown initial promising results. The aim of this prospective, multicentre study was to evaluate 3-year outcomes of aortic arch stent grafting with NEXUS® Aortic Arch Stent Graft System (Nexus), a single-branch, bi-modular, off-the-shelf aortic arch stent graft system in high-risk patients.<br />Methods: Patients treated with Nexus, either under the feasibility clinical study or as compassionate use procedures in 5 centres, were included in this study. The primary end point was overall survival. The secondary end points included the incidence of procedure-related unplanned intervention, stroke, paraplegia and endoleak. Clinical and radiologic follow-up was performed at each study site at 30 days, 6 months and on a yearly basis thereafter up to 3 years postoperatively.<br />Results: We analysed data from a total of 28 patients. The overall median follow-up was 1132 (interquartile range: 809-1537). There were no device or procedure-related deaths between 1 and 3 years. Overall survival at 1 and 3 years was 89% and 71%, respectively. The cumulative incidence of unplanned reintervention at 1 and 3 years was 11% and 29%, respectively. There were no reports of stroke, paraplegia, aneurysm rupture, myocardial infarction or new aortic valve insufficiency. In this study's 1-3 year follow-up period, 1 type Ib (4%), 1 type II (4%) and 2 type III (8%; between Nexus' distal end and Thoracic endovascular aortic repair (TEVAR) extensions) endoleak were detected.<br />Conclusions: Endovascular aortic arch exclusion with the single-branch, off-the-shelf Nexus system provides promising clinical and radiologic results at 3-year follow-up in a high-risk patient cohort.<br /> (© The Author(s) 2022. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.)
- Subjects :
- Humans
Blood Vessel Prosthesis adverse effects
Endoleak epidemiology
Endoleak etiology
Endovascular Aneurysm Repair
Follow-Up Studies
Prospective Studies
Postoperative Complications
Stents adverse effects
Treatment Outcome
Retrospective Studies
Aortic Dissection
Blood Vessel Prosthesis Implantation
Aortic Aneurysm, Thoracic
Endovascular Procedures
Stroke etiology
Subjects
Details
- Language :
- English
- ISSN :
- 1873-734X
- Volume :
- 63
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
- Publication Type :
- Academic Journal
- Accession number :
- 36484696
- Full Text :
- https://doi.org/10.1093/ejcts/ezac561