Back to Search Start Over

Model based development of temperature control schemes for fighter aircraft ECS.

Authors :
Arunachalam S
Varadappan AMS
Source :
Heliyon [Heliyon] 2022 Nov 21; Vol. 8 (11), pp. e11727. Date of Electronic Publication: 2022 Nov 21 (Print Publication: 2022).
Publication Year :
2022

Abstract

The performance of Temperature Control System (TCS), a sub-system of an advanced fighter ECS (Environmental Control System) is studied for its operations both in on-ground and in-air conditions. The standard Bootstrap air cycle system is considered with ACM (Air Cycle Machine) as the main component, which consists of a compressor and a turbine, to produce the cold air. ECS, in particular TCS, is responsible in maintaining the required cockpit or cabin temperature. As the fighter aircraft doesn't require cabin air recirculation, the cabin temperature depends solely on the supply air thermal conditions. The cabin temperature regulation is realized by controlling the supply conditions by maintaining required temperature at ACM outlet and at the entrance duct to the cabin. These temperatures are critical parameters that necessitates appropriate controller to keep the cabin in a good comfortable state. ECS of a fighter aircraft is highly complex and nonlinear than commercial aircraft. The control logics applied, on this system, will drive the actuators or TCVs (Temperature Control Valves) to keep the requisite cabin temperature. The control logics applied on the controller to be simple and appropriate to meet the requirements of fighter aircraft ECS. This shall minimize the control cycle oscillation and subsequent supply air temperature instabilities. This paper explains novel cabin temperature control schemes and their influence on the ECS performance especially during the transient operation. The complete architecture of the control schemes along with system components are modelled in AMESim and the comparison is made for different operating conditions. Finally, a novel variable time-delay based method to control the cabin supply air temperature is proposed.<br />Competing Interests: The authors declare no conflict of interest.<br /> (© 2022 The Author(s).)

Details

Language :
English
ISSN :
2405-8440
Volume :
8
Issue :
11
Database :
MEDLINE
Journal :
Heliyon
Publication Type :
Academic Journal
Accession number :
36468100
Full Text :
https://doi.org/10.1016/j.heliyon.2022.e11727