Back to Search Start Over

Intraoperative aberrometry versus preoperative biometry for intraocular lens power selection in patients with axial hyperopia.

Authors :
Bansal M
Thakur A
Gupta G
Jurangal A
Khanna R
Malhotra C
Gupta A
Jain AK
Source :
Indian journal of ophthalmology [Indian J Ophthalmol] 2022 Dec; Vol. 70 (12), pp. 4295-4299.
Publication Year :
2022

Abstract

Purpose: This study was conducted to evaluate the accuracy of intraoperative aberrometry (IA) in intraocular lens (IOL) power calculation and compare it with conventional IOL formulas.<br />Methods: This was a prospective case series. Eyes with visually significant cataract and axial hyperopia (AL <22.0 mm) underwent IA-assisted phacoemulsification with posterior chamber IOL (Alcon AcrySof IQ). Postoperative spherical equivalent (SE) was compared with predicted SE to calculate the outcomes with different formulas (SRK/T, Hoffer Q, Haigis, Holladay 2, Barrett Universal Ⅱ and Hill-RBF). Accuracy of intraoperative aberrometer was compared with other formulas in terms of mean absolute prediction error (MAE), percentage of patients within 0.5 D and 1 D of their target, and percentage of patients going into hyperopic shift.<br />Results: Sixty-five eyes (57 patients) were included. In terms of MAE, both Hoffer Q (MAE = 0.30) and IA (MAE = 0.32) were significantly better than Haigis, SRK/T, and Barrett Universal Ⅱ (P < 0.05). Outcomes within ±0.5 D of the target were maximum with Hoffer Q (80%), superior to IA (Hoffer Q > IA > Holladay 2 > Hill-RBF > Haigis > SRK/T > Barrett Universal Ⅱ). Hoffer Q resulted in minimum hyperopic shift (30.76%) followed by Hill-RBF (38.46%), Holladay 2 (38.46%), Haigis (43.07%), and then IA (46.15%), SRK/T (50.76%) and Barrett Universal Ⅱ (53.84%).<br />Conclusion: IA was more effective (statistically significant) in predicting IOL power than Haigis, SRK/T, and Barrett Universal Ⅱ although it was equivalent to Hoffer Q. Hoffer Q was superior to all formulas in terms of percentage of patients within 0.5 D of their target refractions and percentage of patients going into hyperopic shift.<br />Competing Interests: None

Details

Language :
English
ISSN :
1998-3689
Volume :
70
Issue :
12
Database :
MEDLINE
Journal :
Indian journal of ophthalmology
Publication Type :
Academic Journal
Accession number :
36453332
Full Text :
https://doi.org/10.4103/ijo.IJO_1307_22