Back to Search
Start Over
Deep Learning Estimation of 10-2 Visual Field Map Based on Circumpapillary Retinal Nerve Fiber Layer Thickness Measurements.
- Source :
-
American journal of ophthalmology [Am J Ophthalmol] 2023 Feb; Vol. 246, pp. 163-173. Date of Electronic Publication: 2022 Nov 01. - Publication Year :
- 2023
-
Abstract
- Purpose: To estimate central 10-degree visual field (VF) map from spectral-domain optical coherence tomography (SD-OCT) retinal nerve fiber layer thickness (RNFL) measurements in glaucoma with artificial intelligence.<br />Design: Artificial intelligence (convolutional neural networks) study.<br />Methods: This study included 5352 SD-OCT scans and 10-2 VF pairs from 1365 eyes of 724 healthy patients, patients with suspected glaucoma, and patients with glaucoma. Convolutional neural networks (CNNs) were developed to estimate the 68 individual sensitivity thresholds of 10-2 VF map using all-sectors (CNN <subscript>A</subscript> ) and temporal-sectors (CNN <subscript>T</subscript> ) RNFL thickness information of the SD-OCT circle scan (768 thickness points). 10-2 indices including pointwise total deviation (TD) values, mean deviation (MD), and pattern standard deviation (PSD) were generated using the CNN-estimated sensitivity thresholds at individual test locations. Linear regression (LR) models with the same input were used for comparison.<br />Results: The CNN <subscript>A</subscript> model achieved an average pointwise mean absolute error of 4.04 dB (95% confidence interval [CI] 3.76-4.35) and correlation coefficient (r) of 0.59 (95% CI 0.52-0.64) over 10-2 map and the mean absolute error and r of 2.88 dB (95% CI 2.63-3.15) and 0.74 (95% CI 0.67-0.80) for MD, and 2.31 dB (95% CI 2.03-2.61) and 0.59 (95% CI 0.51-0.65) for PSD estimations, respectively, significantly outperforming the LR <subscript>A</subscript> model.<br />Conclusions: The proposed CNN <subscript>A</subscript> model improved the estimation of 10-2 VF map based on circumpapillary SD-OCT RNFL thickness measurements. These artificial intelligence methods using SD-OCT structural data show promise to individualize the frequency of central VF assessment in patients with glaucoma and would enable the reallocation of resources from patients at lowest risk to those at highest risk of central VF damage.<br /> (Copyright © 2022 Elsevier Inc. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 1879-1891
- Volume :
- 246
- Database :
- MEDLINE
- Journal :
- American journal of ophthalmology
- Publication Type :
- Academic Journal
- Accession number :
- 36328198
- Full Text :
- https://doi.org/10.1016/j.ajo.2022.10.013