Back to Search Start Over

Stent expansion of restrictive Fontan conduits to nominal diameter and beyond.

Authors :
Salaets T
Cools B
De Meester P
Heying R
Boshoff D
Eyskens B
Brown S
Meyns B
Rega F
Van Puyvelde J
Budts W
Gewillig M
Source :
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions [Catheter Cardiovasc Interv] 2022 Nov; Vol. 100 (6), pp. 1059-1066. Date of Electronic Publication: 2022 Nov 02.
Publication Year :
2022

Abstract

Background: Mechanical factors may cause bottlenecks in a Fontan circuit. Extracardiac conduits (ECC) are placed at a young age, but the materials do not allow growth. Restriction in ECC dimensions may deteriorate the function of the circuit.<br />Aims: This study aimed to evaluate the feasibility and safety of stent expansion of an ECC to the nominal dimension at the time of implant and, if possible, beyond nominal.<br />Methods: Retrospective, single-center observational review of all ECC Fontan patients who received a stent to expand a previously placed surgical conduit.<br />Results: A total of 44 restrictive conduits were stented over a 14-year study period with a median of 11.8 (interquartile ranges [IQR]: 9.1-13.8) years after ECC placement. Cross-sectional areas were a median of 30% (IQR: 21-42) smaller than the originally placed ECC; there was no gradient in 23/44 patients and in 21/44, a minimal gradient of 1.3 ± 0.5 (range 1-3 mmHg). All conduits could be enlarged with a significant (p < 0.0001) increase in diameter from 13.6 ± 1.8 to 19.2 ± 1.2 mm, corresponding to a median cross-sectional area increase of 171% (IQR: 153-220). In three patients where the conduits were not contracted, expansion of between 127% and 165% was obtained. There were no conduit ruptures and only one minor complication.<br />Conclusions: ECC in some Fontan patients become smaller than nominal over time, usually without overt symptoms. The dimensions of ECC's can be safely and significantly increased to nominal or even beyond employing stenting. It allows adjustment of ECC dimensions to compensate for somatic growth.<br /> (© 2022 Wiley Periodicals LLC.)

Details

Language :
English
ISSN :
1522-726X
Volume :
100
Issue :
6
Database :
MEDLINE
Journal :
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
Publication Type :
Academic Journal
Accession number :
36321584
Full Text :
https://doi.org/10.1002/ccd.30438