Back to Search Start Over

Evaluation of qualitative and semi-quantitative cut offs for rapid diagnostic lateral flow test in relation to serology for the detection of SARS-CoV-2 antibodies: findings of a prospective study.

Authors :
Peghin M
Bontempo G
De Martino M
Palese A
Gerussi V
Graziano E
Fabris M
D'Aurizio F
Sbrana F
Ripoli A
Curcio F
Isola M
Tascini C
Source :
BMC infectious diseases [BMC Infect Dis] 2022 Oct 31; Vol. 22 (1), pp. 810. Date of Electronic Publication: 2022 Oct 31.
Publication Year :
2022

Abstract

Background: There is limited information to compare the qualitative and semi-quantitative performance of rapid diagnostic tests (RDT) and serology for the assessment of antibodies against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Therefore, the objective of the study was (a) to compare the efficacy of SARS-CoV-2 antibody detection between RDT and laboratory serology, trying to identify appropriate semi-quantitative cut-offs for RDT in relation with quantitative serology values and to (b) evaluate diagnostic accuracy of RDT compared to the NAAT gold standard in an unselected adult population.<br />Methods: SARS-CoV-2 antibodies were simultaneously measured with lateral flow immunochromatographic assays (LFA), the Cellex qSARS-CoV-2 IgG/IgM Rapid Test (by capillary blood), the iFlash-SARS-CoV-2 IgG/IgM chemiluminescent immunoassay (CLIA) (by venous blood) and the nucleic acid amplification test (NAAT) in samples from in- and out-patients with confirmed, suspected and negative diagnosis of coronavirus disease 2019 (COVID-19) attending Udine Hospital (Italy) (March-May 2020). Interpretation of RDT was qualitative (positive/negative) and semi-quantitative based on a chromatographic intensity scale (negative, weak positive, positive).<br />Results: Overall, 720 paired antibody measures were performed on 858 patients. The qualitative and semiquantitative agreement analysis performed in the whole sample between LFA and CLIA provided a Kendall's tau of 0.578 (pā€‰<ā€‰0.001) and of 0.623 (pā€‰<ā€‰0.001), respectively, for IgM and IgG. In patients with a diagnosis of COVID-19, accordance between LFA and CLIA was maintained as a function of time from the onset of COVID-19 disease and the severity of disease both for qualitative and semi-quantitative assessments. RDT compared to the NAAT gold standard in 858 patients showed 78.5% sensitivity (95% CI 75.1%-81.7%) and 94.1% specificity (95% CI 90.4%-96.8%), with variable accordance depending on the timing from symptom onset.<br />Conclusion: The RDT used in our study can be a non-invasive and reliable alternative to serological tests and facilitate both qualitative and a semi-quantitative antibody detection in COVID-19.<br /> (© 2022. The Author(s).)

Details

Language :
English
ISSN :
1471-2334
Volume :
22
Issue :
1
Database :
MEDLINE
Journal :
BMC infectious diseases
Publication Type :
Academic Journal
Accession number :
36316641
Full Text :
https://doi.org/10.1186/s12879-022-07786-5