Back to Search Start Over

Study on the Ventilation Method to Maintain the PM 10 Concentration in a Subway Cabin below 35 μg/m 3 .

Authors :
Choi ES
Yook SJ
Kim M
Park D
Source :
Toxics [Toxics] 2022 Sep 25; Vol. 10 (10). Date of Electronic Publication: 2022 Sep 25.
Publication Year :
2022

Abstract

The city of Seoul will limit the maximum particulate matter (PM <subscript>10</subscript> ) concentration to ≤35 μg/m <superscript>3</superscript> (from 2024). Herein, a numerical parametric study was conducted on the PM removal efficiency of the heating, ventilation, and air conditioning (HVAC) filters installed in the ceiling of subway cabins. The PM <subscript>10</subscript> concentration distribution was explored according to the flow rate and flow rate ratio of the air introduced into the cabin. Under the current ventilation conditions of the subway train HVAC system, the PM <subscript>10</subscript> concentration was highest in the cabin central area where exhaust outlets are located and decreased toward both ends of the cabin. The indoor airflow was improved and the PM <subscript>10</subscript> concentration was reduced by increasing the flow rate of the supplied air at both ends of the cabin while decreasing it in the central area. It was found that the strengthened PM <subscript>10</subscript> concentration criterion of Seoul can be met by increasing the ventilation flow rate to 700 CMH (currently, 500 CMH) and the filter efficiency to 85% (currently, 70%) while maintaining the current flow rate ratio. These results are expected to be used as important reference data for reducing the PM concentration in subway cabins and thereby improving indoor air quality.

Details

Language :
English
ISSN :
2305-6304
Volume :
10
Issue :
10
Database :
MEDLINE
Journal :
Toxics
Publication Type :
Academic Journal
Accession number :
36287841
Full Text :
https://doi.org/10.3390/toxics10100560