Back to Search Start Over

Device agnostic AI-based analysis of ambulatory ECG recordings.

Authors :
Kennedy A
Doggart P
Smith SW
Finlay D
Guldenring D
Bond R
McCausland C
McLaughlin J
Source :
Journal of electrocardiology [J Electrocardiol] 2022 Sep-Oct; Vol. 74, pp. 154-157. Date of Electronic Publication: 2022 Sep 16.
Publication Year :
2022

Abstract

Deep Convolutional Neural Networks (DCNNs) have been shown to provide improved performance over traditional heuristic algorithms for the detection of arrhythmias from ambulatory ECG recordings. However, these DCNNs have primarily been trained and tested on device-specific databases with standardized electrode positions and uniform sampling frequencies. This work explores the possibility of training a DCNN for Atrial Fibrillation (AF) detection on a database of single‑lead ECG rhythm strips extracted from resting 12‑lead ECGs. We then test the performance of the DCNN on recordings from ambulatory ECG devices with different recording leads and sampling frequencies. We developed an extensive proprietary resting 12‑lead ECG dataset of 549,211 patients. This dataset was randomly split into a training set of 494,289 patients and a testing set of the remaining 54,922 patients. We trained a 34-layer convolutional DCNN to detect AF and other arrhythmias on this dataset. The DCNN was then validated on two Physionet databases commonly used to benchmark automated ECG algorithms (1) MIT-BIH Arrhythmia Database and (2) MIT-BIH Atrial Fibrillation Database. Validation was performed following the EC57 guidelines, with performance assessed by gross episode and duration sensitivity and positive predictive value (PPV). Finally, validation was also performed on a selection of rhythm strips from an ambulatory ECG patch that a committee of board-certified cardiologists annotated. On MIT-BIH, The DCNN achieved a sensitivity of 100% and 84% PPV in detecting episodes of AF. and 100% sensitivity and 94% PPV in quantifying AF episode duration. On AFDB, The DCNN achieved a sensitivity of 94% and PPV of 98% in detecting episodes of AF, and 98% sensitivity and 100% PPV in quantifying AF episode duration. On the patch database, the DCNN demonstrated performance that was closely comparable to that of a cardiologist. The results indicate that DCNN models can learn features that generalize between resting 12‑lead and ambulatory ECG recordings, allowing DCNNs to be device agnostic for detecting arrhythmias from single‑lead ECG recordings and enabling a range of clinical applications.<br />Competing Interests: Declaration of competing Interest Dr Alan Kennedy and Mr Peter Doggart are Founders of PulseAI Ltd.<br /> (Copyright © 2022. Published by Elsevier Inc.)

Details

Language :
English
ISSN :
1532-8430
Volume :
74
Database :
MEDLINE
Journal :
Journal of electrocardiology
Publication Type :
Academic Journal
Accession number :
36283253
Full Text :
https://doi.org/10.1016/j.jelectrocard.2022.09.002