Back to Search
Start Over
Head-to-head comparison of the accuracy of saliva and nasal rapid antigen SARS-CoV-2 self-testing: cross-sectional study.
- Source :
-
BMC medicine [BMC Med] 2022 Oct 24; Vol. 20 (1), pp. 406. Date of Electronic Publication: 2022 Oct 24. - Publication Year :
- 2022
-
Abstract
- Background: The diagnostic accuracy of unsupervised self-testing with rapid antigen diagnostic tests (Ag-RDTs) is mostly unknown. We studied the diagnostic accuracy of a self-performed SARS-CoV-2 saliva and nasal Ag-RDT in the general population.<br />Methods: This large cross-sectional study consecutively included unselected individuals aged ≥ 16 years presenting for SARS-CoV-2 testing at three public health service test sites. Participants underwent molecular test sampling and received two self-tests (the Hangzhou AllTest Biotech saliva self-test and the SD Biosensor nasal self-test by Roche Diagnostics) to perform themselves at home. Diagnostic accuracy of both self-tests was assessed with molecular testing as reference.<br />Results: Out of 2819 participants, 6.5% had a positive molecular test. Overall sensitivities were 46.7% (39.3-54.2%) for the saliva Ag-RDT and 68.9% (61.6-75.6%) for the nasal Ag-RDT. With a viral load cut-off (≥ 5.2 log10 SARS-CoV-2 E-gene copies/mL) as a proxy of infectiousness, these sensitivities increased to 54.9% (46.4-63.3%) and 83.9% (76.9-89.5%), respectively. For the nasal Ag-RDT, sensitivities were 78.5% (71.1-84.8%) and 22.6% (9.6-41.1%) in those symptomatic and asymptomatic at the time of sampling, which increased to 90.4% (83.8-94.9%) and 38.9% (17.3-64.3%) after applying the viral load cut-off. In those with and without prior SARS-CoV-2 infection, sensitivities were 36.8% (16.3-61.6%) and 72.7% (65.1-79.4%). Specificities were > 99% and > 99%, positive predictive values > 70% and > 90%, and negative predictive values > 95% and > 95%, for the saliva and nasal Ag-RDT, respectively, in most analyses. Most participants considered the self-performing and result interpretation (very) easy for both self-tests.<br />Conclusions: The Hangzhou AllTest Biotech saliva self Ag-RDT is not reliable for SARS-CoV-2 detection, overall, and in all studied subgroups. The SD Biosensor nasal self Ag-RDT had high sensitivity in individuals with symptoms and in those without prior SARS-CoV-2 infection but low sensitivity in asymptomatic individuals and those with a prior SARS-CoV-2 infection which warrants further investigation.<br /> (© 2022. The Author(s).)
Details
- Language :
- English
- ISSN :
- 1741-7015
- Volume :
- 20
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- BMC medicine
- Publication Type :
- Academic Journal
- Accession number :
- 36280827
- Full Text :
- https://doi.org/10.1186/s12916-022-02603-x