Back to Search Start Over

Gamma counting protocols for the accurate quantification of 225 Ac and 213 Bi without the need for a secular equilibrium between parent and gamma-emitting daughter.

Authors :
Castillo Seoane D
De Saint-Hubert M
Ahenkorah S
Saldarriaga Vargas C
Ooms M
Struelens L
Koole M
Source :
EJNMMI radiopharmacy and chemistry [EJNMMI Radiopharm Chem] 2022 Oct 23; Vol. 7 (1), pp. 28. Date of Electronic Publication: 2022 Oct 23.
Publication Year :
2022

Abstract

Background: Quantification of actinium-225 through gamma counter measurements, when there is no secular equilibrium between actinium-225 and its gamma emitting daughters bismuth-213 and/or francium-221, can provide valuable information regarding the possible relocation of recoiled daughters such that related radiotoxicity effects can be evaluated. This study proposes a multiple time-point protocol using the bismuth-213 photopeak with measurements before secular equilibrium between actinium-225 and bismuth-213, and a single time-point protocol using both the francium-221 and bismuth-213 photopeak while assuming secular equilibrium between actinium-225 and francium-221 but not between bismuth-213 and actinium-225.<br />Results: Good agreement (i.e. 3% accuracy) was obtained when relying on a multiple time-points measurement of bismuth-213 to quantify both actinium-225 and excess of bismuth-213. Following scatter correction, actinium-225 can be accurately quantified using the francium-221 in a single time-point measurement within 3% of accuracy. The analysis performed on the stability data of [ <superscript>225</superscript> Ac]Ac-DEPA and [ <superscript>225</superscript> Ac]Ac-DOTA complexes, before secular equilibrium between bismuth-213 and actinium-225 was formed, revealed considerable amounts of unbound bismuth-213 (i.e. more than 90%) after 24 h of the radiolabeling most likely due to the recoiled daughter effect.<br />Conclusion: Both protocols were able to accurately estimate <superscript>225</superscript> Ac-activities provided the francium-221 energy window was corrected for the down scatter of the higher-energy gamma-emissions by bismuth-213. This could prove beneficial to study the recoiled daughter effect and redistribution of free bismuth-213 by monitoring the accumulation or clearance of bismuth-213 in different tissues during biodistribution studies or in patient samples during clinical studies. On the other hand, the single gamma counter measurement protocol, although required a 30 min waiting time, is more time and cost efficient and therefore more appropriate for standardized quality control procedures of <superscript>225</superscript> Ac-labeled radiopharmaceuticals.<br /> (© 2022. The Author(s).)

Details

Language :
English
ISSN :
2365-421X
Volume :
7
Issue :
1
Database :
MEDLINE
Journal :
EJNMMI radiopharmacy and chemistry
Publication Type :
Academic Journal
Accession number :
36274098
Full Text :
https://doi.org/10.1186/s41181-022-00174-z