Back to Search Start Over

The utility of WhatsApp-based off-site evaluation for rapid cytology of EBUS-TBNA samples.

Authors :
Damaraju V
Gupta N
Saini M
Dhooria S
Prasad KT
Gupta P
Muthu V
Aggarwal AN
Agarwal R
Sehgal IS
Source :
Cytopathology : official journal of the British Society for Clinical Cytology [Cytopathology] 2023 Jan; Vol. 34 (1), pp. 43-47. Date of Electronic Publication: 2022 Nov 13.
Publication Year :
2023

Abstract

Background: Whether off-site evaluation of slides by a cytologist viewing the images shared by WhatsApp improves the on-site evaluation by a pulmonologist (P-ROSE) remains unknown. This study's objective was to compare the sensitivity of P-ROSE and WHOSE for adequacy and diagnosis of cytology specimens obtained by endobronchial ultrasound (EBUS)-guided transbronchial needle aspiration (TBNA).<br />Materials and Methods: We retrospectively reviewed our bronchoscopy database to identify subjects who underwent EBUS-TBNA for lymph node sampling and had reports of P-ROSE and WHOSE. We collected data on the adequacy of samples as reported by the pulmonologist (P-ROSE), remotely by the cytologist (WHOSE), and finally after detailed cytologic evaluation. The study's primary outcome was to assess the increment in sensitivity for adequacy and diagnostic category (using the final cytology report as reference) by incorporating WHOSE.<br />Results: We included 264 (P-ROSE, n = 184; WHOSE, n = 80) subjects. The sensitivity (95% CI) for sample adequacy by P-ROSE and WHOSE was 65.3% (57.9%-72%) and 92% (83.6%-96.2%), respectively. There was a 26.6% (95% CI, 16%-35.2%) increment in the sensitivity for adequacy. The sensitivity (95% CI) for diagnosis by P-ROSE and WHOSE was 53.9% (46%-61.1%) and 89.8% (79.5%-95.3%), respectively. There was a 35.9% (95% CI, 23.4%-45%) increment in the sensitivity for diagnosis with WHOSE. The agreement between P-ROSE and final cytology in adequacy was poor (κ = -0.023, p = 0.616). The agreement between WHOSE and final cytology was moderate for adequacy (κ = 0.491, p = <0.001).<br />Conclusion: We found WHOSE significantly improves the performance of P-ROSE for rapid assessment of cytology specimens obtained by EBUS-TBNA.<br /> (© 2022 John Wiley & Sons Ltd.)

Details

Language :
English
ISSN :
1365-2303
Volume :
34
Issue :
1
Database :
MEDLINE
Journal :
Cytopathology : official journal of the British Society for Clinical Cytology
Publication Type :
Academic Journal
Accession number :
36251524
Full Text :
https://doi.org/10.1111/cyt.13188