Development and Validation of a Point-of-Care-Ultrasound Image Quality Assessment Tool: The POCUS IQ Scale.

Authors :
Dessie AS
Calhoun AW
Kanjanauptom P
Gilbert GE
Ekpenyong A
Lewiss RE
Rabiner JE
Tsze DS
Kessler DO
Source :
Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine [J Ultrasound Med] 2023 Jan; Vol. 42 (1), pp. 135-145. Date of Electronic Publication: 2022 Sep 27.
Publication Year :
2023

Abstract

Objectives: We aimed to develop a standardized scoring tool to measure point-of-care ultrasound (POCUS) image quality and to determine validity evidence for its use to assess lung ultrasound image quality.<br />Methods: The POCUS Image Quality (POCUS IQ) scale was developed by POCUS-trained physicians to assess sonographers' image acquisition skills by evaluating image quality for any POCUS application. The scale was piloted using lung images of healthy standardized patients acquired by three expert sonographers compared to three novices before and after training. All images (experts, novices pre-training, novices post-training) were scored on the POCUS IQ scale by three blinded POCUS-trained physicians. Reliability was assessed with fully-crossed generalizability and decision studies. Validity was assessed using Messick's framework.<br />Results: Content validity was supported by the tool's development process of literature review, expert consensus, and pilot testing. Response process was supported by reviewer training and the blinded scoring process. Relation to other variables was supported by scores relating to sonographer experience: median expert score = 10.5/14 (IQR: 4), median novice pre-training score = 6/14 (IQR: 2.25), and novices' improvement after training (median post-training score = 12/14, IQR: 3.25). Internal structure was supported by internal consistency data (coefficient alpha = 0.84, omega coefficient = 0.91) and the generalizability study showing the main contributor to score variability was the sonographer (51%). The G-coefficient was 0.89, suggesting very good internal structure, however, Gwet's AC <subscript>2</subscript>  was 0.5, indicating moderate interrater reliability. The D study projected a minimum of 1 reviewer and 2 patients are needed for good psychometric reliability.<br />Conclusions: The POCUS scale has good preliminary validity evidence as an assessment tool for lung POCUS image acquisition skills. Further studies are needed to demonstrate its utility for other POCUS applications and as a feedback tool for POCUS learners.<br /> (© 2022 American Institute of Ultrasound in Medicine.)

Details

Language :
English
ISSN :
1550-9613
Volume :
42
Issue :
1
Database :
MEDLINE
Journal :
Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine
Publication Type :
Academic Journal
Accession number :
36165271
Full Text :
https://doi.org/10.1002/jum.16095