Back to Search Start Over

Suitability of propagated contours for adaptive replanning for head and neck radiotherapy.

Authors :
Nash D
Palmer AL
van Herk M
McWilliam A
Vasquez Osorio E
Source :
Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) [Phys Med] 2022 Oct; Vol. 102, pp. 66-72. Date of Electronic Publication: 2022 Sep 18.
Publication Year :
2022

Abstract

Purpose: Adaptive radiotherapy relies on rapid recontouring for replanning. Contour propagation offers workflow efficiencies, but the impact of using unedited propagated OAR contours directly during re-optimisation is unclear.<br />Methods: Plans for ten head and neck patients were created on the planning CT scan. OAR contours for the spinal cord, brainstem, parotids and larynx were then propagated to five shading-corrected CBCTs equally spaced throughout treatment using five commercial packages. Two reference contours were created on the CBCTs by (1) a clinician and (2) a geometric consensus from the propagated contours. Treatment plans were re-optimised on each CBCT for each set of contours, and the DVH statistic differences to the reference contours were calculated. The spread of DVH statistic differences between the 5th and 95th percentiles was quantified.<br />Results: The spread of DVH statistic differences was 3.7 Gy compared to the clinician contour and 3.3 Gy compared to the consensus contour for the brainstem (and PRV) and 2.4 Gy and 2 Gy for the spinal cord (and PRV), across all 5 auto-contouring solutions. The parotids and larynx showed differences of 3.7 Gy compared to the clinician and 0.9 Gy to the consensus contour, with the larger difference for the clinician possibly caused by uncertainty in the clinician standard due to poor image quality on the CBCTs.<br />Conclusions: Propagated OAR contours can be used safely for adaptive radiotherapy replanning, however, where organ doses are close to clinical tolerance then the contours should be reviewed for accuracy regardless of the propagation software used.<br />Competing Interests: Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.<br /> (Copyright © 2022 Associazione Italiana di Fisica Medica e Sanitaria. Published by Elsevier Ltd. All rights reserved.)

Details

Language :
English
ISSN :
1724-191X
Volume :
102
Database :
MEDLINE
Journal :
Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)
Publication Type :
Academic Journal
Accession number :
36126469
Full Text :
https://doi.org/10.1016/j.ejmp.2022.09.002