Back to Search Start Over

Sensitivity and specificity of automated blood pressure devices to detect atrial fibrillation: A systematic review and meta-analysis of diagnostic accuracy.

Authors :
Tang EWL
Yip BHK
Yu CP
Wong SYS
Lee EKP
Source :
Frontiers in cardiovascular medicine [Front Cardiovasc Med] 2022 Aug 12; Vol. 9, pp. 956542. Date of Electronic Publication: 2022 Aug 12 (Print Publication: 2022).
Publication Year :
2022

Abstract

Background: Atrial fibrillation (AF) is a prevalent and preventable cause of stroke and mortality.<br />Aim: This systematic review and meta-analysis aimed to investigate the sensitivity and specificity of office and out-of-office automated blood pressure (BP) devices to detect AF.<br />Methods: Diagnostic studies, extracted from databases such as Ovid Medline and Embase, on AF detection by BP device(s), electrocardiography, and reported sensitivity and specificity, were included. Screening of abstracts and full texts, data extraction, and quality assessment were conducted independently by two investigators using Covidence software. The sensitivity and specificity of the BP devices were pooled using a random-effects model.<br />Results: Sixteen studies including 10,158 participants were included. Only a few studies were conducted in primary care ( n = 3) or with a low risk of bias ( n = 5). Office BP devices, which utilised different algorithms to detect AF, had a sensitivity and specificity of 96.2 and 94%, respectively. Specificity was reduced when only one positive result was considered among consecutive BP measurements. Only a few studies ( n = 3) investigated out-of-office BP. Only one study ( n = 100) suggested the use of ≥79 and ≥26% of positive readings on 24-h ambulatory BP measurements to detect AF and paroxysmal AF, respectively.<br />Conclusions: Office BP devices can be used clinically to screen for AF in high-risk populations. Clinical trials are needed to determine the effect of AF screening using office BP devices in reducing stroke risk and mortality. Further studies are also required to guide out-of-office use of BP devices for detecting paroxysmal AF or AF.<br />Systematic Review Registration: https://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42022319541, PROSPERO CRD42022319541.<br />Competing Interests: The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.<br /> (Copyright © 2022 Tang, Yip, Yu, Wong and Lee.)

Details

Language :
English
ISSN :
2297-055X
Volume :
9
Database :
MEDLINE
Journal :
Frontiers in cardiovascular medicine
Accession number :
36035905
Full Text :
https://doi.org/10.3389/fcvm.2022.956542