Back to Search Start Over

The efficacy of gonadotropin-releasing hormone agonist treatment before hysteroscopic myomectomy for large-sized submucosal leiomyoma.

Authors :
Park M
Song MS
Kang BH
Song SY
Lee GW
Jung YW
Shin WK
Ko YB
Lee KH
Yoo HJ
Source :
Medicine [Medicine (Baltimore)] 2022 Aug 05; Vol. 101 (31), pp. e29726.
Publication Year :
2022

Abstract

To evaluate the efficacy and safety of a gonadotropin-releasing hormone (GnRH) agonist for treating large-sized submucosal leiomyoma before hysteroscopic myomectomy. The data were retrospectively collected from patients who underwent a hysteroscopic myomectomy for a submucosal leiomyoma >3.5 cm in size from January 2009 to December 2018. The patients were divided into the GnRH group and the control group according to whether they were pretreated before surgery. A total of 61 patients were included in the study, 31 in the GnRH agonist group and 30 in the control group. At diagnosis, the maximum leiomyoma diameter was similar between the 2 groups (4.67 ± 0.6 cm in the GnRH agonist group vs 3.82 ± 0.6 cm in the control group, P = .061). After pretreatment with the GnRH agonist, the maximum diameter was significantly smaller in the GnRH agonist group compared to the control group (3.82 ± 0.6 vs 4.33 ± 0.8 cm, respectively, P = .004). The leiomyoma volume in the GnRH agonist group decreased by 55.6%, from 41.68 ± 15.7 to 23.19 ± 10.4 cm3, which led to significant differences in leiomyoma volume between the 2 groups (23.19 ± 10.4 cm3 in the GnRH agonist group vs 33.22 ± 24.7 cm3 in the control group, P = .042). The GnRH agonist group showed a shorter operation time (37.7 vs 43.9 minutes, P = .040) and less uterine distention media was used (6800 vs 9373.3 mL, P = .037) compared to the control group. Postoperative complications such as estimated blood loss, remnant leiomyoma, and recurrence were similar between the 2 groups. Treatment with a GnRH agonist before hysteroscopic myomectomy for large submucosal leiomyoma might decrease the volume of the leiomyoma, reduce operation time, and the amount of uterine-distension media used without surgical complications.<br />Competing Interests: The authors have no conflicts of interest to disclose.<br /> (Copyright © 2022 the Author(s). Published by Wolters Kluwer Health, Inc.)

Details

Language :
English
ISSN :
1536-5964
Volume :
101
Issue :
31
Database :
MEDLINE
Journal :
Medicine
Publication Type :
Academic Journal
Accession number :
35945797
Full Text :
https://doi.org/10.1097/MD.0000000000029726