Back to Search Start Over

A Single-center Prospective Observational Study Investigating the Accuracy of Preoperative Diagnostic Procedures in the Assessment of Lymph Node Metastases in Nonfunctioning Pancreatic Neuroendocrine Tumors.

Authors :
Partelli S
Muffatti F
Andreasi V
Giannone F
Rossi G
Palumbo D
Mapelli P
Schiavo Lena M
Arcidiacono PG
De Cobelli F
Picchio M
Doglioni C
Falconi M
Source :
Annals of surgery [Ann Surg] 2022 Nov 01; Vol. 276 (5), pp. 921-928. Date of Electronic Publication: 2022 Aug 05.
Publication Year :
2022

Abstract

Objective: To determine the accuracy of preoperative imaging, including contrast-enhanced computed tomography (CE-CT), endoscopic ultrasound (EUS), and 68 Gallium-DOTATOC positron emission tomography ( 68 Ga-DOTATOC PET), in identifying nodal metastases (N+) in sporadic nonfunctioning pancreatic neuroendocrine tumors (NF-PanNETs).<br />Background: An accurate preoperative identification of N+ in NF-PanNETs is critical for surgical planning. The accuracy of different imaging techniques in detecting lymph node (LN) metastases in NF-PanNETs has been poorly investigated.<br />Methods: All consecutive patients undergoing surgery for sporadic NF-PanNETs (2018-2021) were enrolled in a prospective study (DETECTYON; NCT03918759). The accuracy of preoperative imaging techniques in detecting N+ was assessed through sensitivity, specificity positive and negative predictive values.<br />Results: Overall, 100 patients with NF-PanNETs underwent CE-CT, EUS, and 68 Ga-DOTATOC PET before pancreatic resection. LN metastases were found in 42 cases (42%). Sensitivity, specificity, positive predictive value, and negative predictive value of different imaging techniques were 26%, 95%, 79%, 64% for CE-CT, 19%, 98%, 89%, 63% for EUS, and 12%, 95%, 63%, 60% for 68 Ga-DOTATOC PET, respectively. Radiologic tumor size >4 cm and the presence of radiologic N+ at ≥1 imaging were independent predictors of N+ at pathology. The identification of N+ at ≥1 imaging technique was associated with a higher number of positive LNs compared with negative imaging (4 vs 2) ( P =0.012).<br />Conclusions: CE-CT, EUS, and 68 Ga-DOTATOC PET are poorly sensitive in predicting nodal status in NF-PanNETs despite a high specificity.<br />Competing Interests: The authors report no conflicts of interest.<br /> (Copyright © 2022 Wolters Kluwer Health, Inc. All rights reserved.)

Details

Language :
English
ISSN :
1528-1140
Volume :
276
Issue :
5
Database :
MEDLINE
Journal :
Annals of surgery
Publication Type :
Academic Journal
Accession number :
35930017
Full Text :
https://doi.org/10.1097/SLA.0000000000005615