Validation of a Denoising Method Using Deep Learning-Based Reconstruction to Quantify Multiple Sclerosis Lesion Load on Fast FLAIR Imaging.

Authors :
Yamamoto T
Lacheret C
Fukutomi H
Kamraoui RA
Denat L
Zhang B
Prevost V
Zhang L
Ruet A
Triaire B
Dousset V
Coupé P
Tourdias T
Source :
AJNR. American journal of neuroradiology [AJNR Am J Neuroradiol] 2022 Aug; Vol. 43 (8), pp. 1099-1106. Date of Electronic Publication: 2022 Jul 28.
Publication Year :
2022

Abstract

Background and Purpose: Accurate quantification of WM lesion load is essential for the care of patients with multiple sclerosis. We tested whether the combination of accelerated 3D-FLAIR and denoising using deep learning-based reconstruction could provide a relevant strategy while shortening the imaging examination.<br />Materials and Methods: Twenty-eight patients with multiple sclerosis were prospectively examined using 4 implementations of 3D-FLAIR with decreasing scan times (4 minutes 54 seconds, 2 minutes 35 seconds, 1 minute 40 seconds, and 1 minute 15 seconds). Each FLAIR sequence was reconstructed without and with denoising using deep learning-based reconstruction, resulting in 8 FLAIR sequences per patient. Image quality was assessed with the Likert scale, apparent SNR, and contrast-to-noise ratio. Manual and automatic lesion segmentations, performed randomly and blindly, were quantitatively evaluated against ground truth using the absolute volume difference, true-positive rate, positive predictive value, Dice similarity coefficient, Hausdorff distance, and F1 score based on the lesion count. The Wilcoxon signed-rank test and 2-way ANOVA were performed.<br />Results: Both image-quality evaluation and the various metrics showed deterioration when the FLAIR scan time was accelerated. However, denoising using deep learning-based reconstruction significantly improved subjective image quality and quantitative performance metrics, particularly for manual segmentation. Overall, denoising using deep learning-based reconstruction helped to recover contours closer to those from the criterion standard and to capture individual lesions otherwise overlooked. The Dice similarity coefficient was equivalent between the 2-minutes-35-seconds-long FLAIR with denoising using deep learning-based reconstruction and the 4-minutes-54-seconds-long reference FLAIR sequence.<br />Conclusions: Denoising using deep learning-based reconstruction helps to recognize multiple sclerosis lesions buried in the noise of accelerated FLAIR acquisitions, a possibly useful strategy to efficiently shorten the scan time in clinical practice.<br /> (© 2022 by American Journal of Neuroradiology.)

Details

Language :
English
ISSN :
1936-959X
Volume :
43
Issue :
8
Database :
MEDLINE
Journal :
AJNR. American journal of neuroradiology
Publication Type :
Academic Journal
Accession number :
35902124
Full Text :