[Successful Removal of Intrapericardial Needle using Needle Guidance System].
- Source :
-
Kyobu geka. The Japanese journal of thoracic surgery [Kyobu Geka] 2022 Aug; Vol. 75 (8), pp. 593-597. - Publication Year :
- 2022
-
Abstract
- A 41-year-old man stuck himself with needle through his pericardium during suicide attempt. Chest radiography revealed several needles in the bilateral lung fields as well. Computed tomography (CT) and echocardiography showed massive pericardial effusion and a needle penetrating the pericardium. The patient was initially treated conservatively, including pericardial drainage, and, seven days later, we removed the needle using syngo Needle Guidance in hybrid operating room. The length of skin incision was only 2 cm, and the postoperative course was uneventful. No previous studies, to the best of our knowledge, have shown the use of syngo Needle Guidance to remove a needle in the pericardial cavity. This surgical procedure is minimally invasive for the patient.
Details
- Language :
- Japanese
- ISSN :
- 0021-5252
- Volume :
- 75
- Issue :
- 8
- Database :
- MEDLINE
- Journal :
- Kyobu geka. The Japanese journal of thoracic surgery
- Publication Type :
- Academic Journal
- Accession number :
- 35892297